User's Manual

Operation
ALPRO ver 6.60/ Activity meter system
94118201.pdf2006-11-08
stops when a key is pressed. If no beep is
wanted it can be turned off in the general
setup, address 6:1:1
The activity alarms inform you about cows
with tags which messages have not been
received for a certain time period or they
have sent a zero data, meaning that no
movements have been recorded.
The activity alarms can be seen in display
1:2:4 ACTIVITY ALARMS. The events
causing alarms are:
ACTIVITY ALARM
ALL
48 HOURS NO ACTIVITY COW NO: 5342
CLEAR THIS ALARM: NO
CLEAR ALL ALARMS: NO
FIRST ALARM
48 HOURS NO ACTIVITY ALARM - the tag
has reported that no movements have been
registered during the last 48 hours.
- This means usually that the cow either
has lost her tag or her tag has been
removed.
48 HOURS NO RF SENDING - no data has
been received from the tag for 48 hours.
24 HOURS NO RF SENDING - no data has
been received from the tag for 24 hours.
GENERAL SETUP
COMM. BAUD RATE: 57600
NO RF SENDING: 00 HOURS
SELECT UNIT OF WEIGHT: KG/TON
SOUND: YES
NO RF SENDING - no data has been
received from the tag for a time period set
by the user.
- Those three alarms mean that the tag is
out of range from the antenna or that the
tag has stopped sending.
The No RF sending is by default switched
off, i.e. the time is set to 00 HOURS.
Settings are made in the general setup,
address 6:1:1.
Clear alarms
Set CLEAR THIS ALARM to YES and press
ENTER and the displayed alarm will be
removed.
Set CLEAR ALL ALARMS to YES and
choose ALL on the first row to remove all
alarms.
Set CLEAR ALL ALARMS to YES and
choose a type of alarm in the first row to
remove all alarms of this type.
28(60)