User's Manual

Program description
ALPRO ver 6.60/ Activity meter system
94118201.pdf2006-11-08
6:1:6:4:5 GROUP DATA
GROUP DATA
GIVE HIGH ACTIVITY ALARM:
YES
SENSITIVITY
:
GENERAL ACTIVITY TYPE:
STAT E
GROUP NO:
1
HOURS:
2
(2)
In this display it is possible to set activity
parameters for a group of cows.
High activity alarm could be turned off. Then
set GIVE HIGH ACTIVITY ALARM to NO.
General activity type is recommended to be
set to STATE. CONTINOUS is a very
sensitive setting used only to detect low
activity. It can only be used for a group of
cows with very settled activity pattern and is
hanled in ALPRO Windows. See ALPRO/
Activity meter system.
The sensitivity level can be set between 1
and 5. It refers to how many hours of
activity that should pass before ALPRO
makes an alarm. The value in paranthesis
refer to the system setting in menu 6:1:6:4:1.
6:1:6:5 RF TIME DIAGNOSTICS
RF TIME DIAG. TIME TIME
ANTENNA NO: 1 12:34:25 12:28:12
ADDRESS: 4 12:32:12 12:26:34
TAG NO: 12345 12:31:05 12:24:27
12:29:10 ---:---:---
This function is used for detecting the range
of the RF antenna, to estimate the size of
the area where the antennas can receive a
sending.
Select a RF-interface.
Select a tag and enter the number that we
want to use for the test.
RF TIME DIAG. TIME ANT TIM ANT
ANTENNA NO: 0 12:34:25 2 ---:---:---
ADDRESS: 2 12:32:12 4 ---:---:---
TAG NO: 12345 12:31:05 5 ---:---:---
12:29:10 4 ---:---:---
Every time we get a sending from that tag,
i.e. striking the magnet on the tag, we set a
time stamp on the screen and a beep is
heard from the processor's speaker.
If antenna No. is set to 0 a new column is
added showing the antenna no. of the
connected antennas. It is then possible to
detect if one sending is received by more
than one antenna. The display will show the
last received sending and from which
antenna No.
53(60)