STOPPING THE CLEANER
1) After use with detergent,
rinse the high pressure water
circuit by operating the pump
for one minute with the deter-
gent tap completely closed.
(g. 8).
2) Stop the cleaner by tur-
ning the selector switch to pos.
"0" (g. 6A).
3) Discharge the pressure
from the H.P. hose by pressing
the trigger on the gun (g.
5A).
4) Disconnect the water
cleaner from the electricity
supply by removing the plug
from the socket.
5) Turn off the water supply
(g. 4A).
If the water cleaner is left,
even temporarily, turn it off by
using the on/off switch or by
unplugging the plug from the
socket.
Water cleaners with the
“Total Stop” device should be
considered as off when the on/
off switch is in the “O” position
or the plug is unplugged from
the socket.
When the water cleaner
is not used, close the safety
device on the handle (g. 9).
Dry use of the water clea
-
ner causes serious damage to
pump gaskets.
USING
THE CLEANER
CONTROL PANEL
A - On/off switch
B - Detergent control tap.
STARTING THE CLEANER
1) Turn on the water supply
(g. 4A).
2) Connect the water cleaner
to the electricity supply by
inserting the plug into the
socket.
3) Start the cleaner by turning
the selector switch to pos. 1
(g. 6A).
Keep a rm grip on the lance
handle.
4) Press the trigger on the gun
and begin washing.
In water cleaners with the
“Total Stop” system, the motor
starts and stops when the
trigger on the gun is activated
or released.
Do not block the handle
lever in the ON position.
IMPORTANT!
To eliminate any impurities
or air bubbles from the wa-
ter circuit we advise starting
the cleaner for the rst time
without the lance and letting
the water run out for a few
seconds.
Impurities could block the
nozzle and cause malfunc-
tion (Fig. 7).
FIG. 8
FIG. 6
FIG. 7
FIG. 9
!
!
!
!
!
!
A
B