Delfield ™ ® 6000XL & 6100XL Series Reach Ins Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2.
6000XL Series Service and Installation Manual Contents Serial Number Information......................................................... 2 Receiving & Inspecting Equipment............................................ 2 Specifications.............................................................................. 3 Installation................................................................................... 4 Door Reversal Procedures..........................................................
6000XL Series Service and Installation Manual Specifications Voltage Amps Storage Capacity FT3 Shelf Capacity FT2 H.P. BTU/HR Evap. Temp R-404A Charge Oz. Shipping Weight Nema Plug 6025XL-SH,S 115 6.0 20.0 15.1 1/4 2092 20˚F 12.5 274lbs/124kg 5-15p 6025XL-G,GH 115 6.0 20.0 15.1 1/4 2092 20˚F 12.5 338lbs/153kg 5-15p 6051XL-SH,S 115 8.0 43.5 33.2 1/3 2488 20˚F 12.5 454lbs/206kg 5-15p 6051XL-G,GH 115 8.0 43.5 33.2 1/3 2488 20˚F 12.
6000XL Series Service and Installation Manual Installation Location Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded 6000XL series can weigh as much as 1500 pounds. Reinforce the floor as necessary to provide for maximum loading. For the most efficient refrigeration, be sure to provide good air circulation inside and out.
6000XL Series Service and Installation Manual Door Reversal Procedures Standard Edge-Mount Hinge Only for Models Ordered With Re-Hinging Option 1. 2. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Open door 90˚ and lift door straight up and off hinges. Remove the metal screw covers on each door-side hinge section by sliding it down and off. Remove two outer screws that mount each hinge to door, loosen the center screw, rotate hinge 180˚, reinstall outer screws and retighten center screw.
000XL Series Service and Installation Manual Operation Electronic Temperature Control Operation: The electronic temperature control constantly monitors box temperature as well as evaporator coil temperature to maintain consistent product temperatures. The control also sends temperature readings to the digital temperature display. The control circuits continually self-check and if an error occurs, the digital display will switch from temperature read-out to error read-out, i.e. E 1.
6000XL Series Service and Installation Manual Maintenance The thermostat must be turned to OFF and the unit disconnected from the power source whenever performing service, maintenance functions or cleaning the refrigerated area. Refrigerators and Freezers The interior and exterior can be cleaned using soap and warm water. If this isn’t sufficient, try ammonia and water or a nonabrasive liquid cleaner.
6000XL Series Service and Installation Manual Maintenance, continued If your freezer seems to vibrate excessively when the compressor is running, loosen (but do not remove) the bolts on the compressor. Semi hermetic models should be loosened before operating. BASIC MAINTENANCE Gasket Maintenance Gaskets require regular cleaning to prevent mold and mildew build up and also to keep the elasticity of the gasket. Gasket cleaning can be done with the use of warm soapy water.
6000XL Series Service and Installation Manual Wiring Diagrams: Refrigerators 6025XL-S, 6025XL-SH L1 NOTES: 1) USE COPPER CONDUCTORS ONLY 2) THIS UNIT MUST BE GROUNDED 3) UNIT SHOWN WITH COMPRESSOR RUNNING AND DOORS CLOSED N LINE VOLTAGE 115/60/1 SEE NAMEPLATE FOR MAXIMUM FUSE SIZE EVAPORATOR HOUSING EVAP FAN MOTOR M PLUG CONTROL CIRCUIT N 5 C COMPRESSOR RELAY BLUE M 1 INCANDESCENT LIGHT COMPRESSOR W WITH BLUE STRIPES W 1.1,2,3 2.1,2,3 3.
6000XL Series Service and Installation Manual Wiring Diagrams: Refrigerators 6051XL-S, 6051XL-SH 6051XL-G, 6051XL-GH Delfield ™ 10 For customer service, call (800) 733-8829, (800) 733-8821, Fax (888) 779-2040, www.delfield.
6000XL Series Service and Installation Manual Wiring Diagrams: Refrigerators 6076XL-S, 6076XL-SH 6076XL-G, 6076XL-GH Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (888) 779-2040, www.delfield.
6000XL Series Service and Installation Manual Wiring Diagrams: Freezers 6125XL-S, 6125XL-SH L1 N LINE VOLTAGE 115/60/1 SEE NAMEPLATE FOR MAXIMUM FUSE SIZE NOTES: 1) USE COPPER CONDUCTORS ONLY 2) THIS UNIT MUST BE GROUNDED 3) UNIT SHOWN WITH COMPRESSOR RUNNING AND DOORS CLOSED EVAPORATOR HOUSING EVAP FAN MOTOR Y N CONTROL CIRCUIT PLUG 5 M DEFROST HEATER EVAP COIL SENSOR BLUE F 6 FAN RELAY CABINET AIR SENSOR L 3 HIGH TEMP LIMIT SWITCH M TEMPERATURE CONTROL EVAPORATOR FAN INCANDESCENT LIGH
6000XL Series Service and Installation Manual Wiring Diagrams: Freezers 6151XL-S, 6151XL-SH L1 N LINE VOLTAGE 115/60/1 SEE NAMEPLATE FOR MAXIMUM FUSE SIZE NOTES: 1) USE COPPER CONDUCTORS ONLY 2) THIS UNIT MUST BE GROUNDED 3) UNIT SHOWN WITH COMPRESSOR RUNNING AND DOORS CLOSED EVAPORATOR HOUSING EVAP FAN MOTOR Y N BLUE F FAN RELAY PLUG 5 M 6 DEFROST HEATER EVAP COIL SENSOR CONTROL CIRCUIT 3 CABINET AIR SENSOR L HIGH TEMP LIMIT SWITCH M TEMPERATURE CONTROL EVAPORATOR FAN INCANDESCENT LIG
6000XL Series Service and Installation Manual Refrigeration Package Diagram 17 16 4 7 15 18 5 12 6 14 11 9 1 3 8 21 13 9 14 11 7 1 15 16 4 5 6 17 21 19 20 3 2 18 Delfield ™ 14 For customer service, call (800) 733-8829, (800) 733-8821, Fax (888) 779-2040, www.delfield.
6000XL Series Service and Installation Manual Refrigeration Package - Replacement Parts Refrigerator - 1 section & 3 section left package Item Number Part Number 1 2 (kit) 3 4 5 6 7 8 9 11 12 13 14 15 15 16 16 17 17 18 3516437 2194782KT 2190154 2184181 2162715 3517390 3516588 3516205 3516427 127-C33-0036 2162717 3516432 2160019 3526999 220V/50Hz Part# 2194988KT 2162719 2192720 3527013 3516444 117U6002 2194787 117U5015 3516322 1702795 3516041 Freezer- 1 section & 3 section left package Description
6000XL Series Service and Installation Manual Replacement Parts Miscellaneous Replacement Parts Part Number 2194791 3235514 3234778 3234779 2194792 3239590 3234791 3978270 3978277 3978278 Description Cable Casters, rigid, One section only Casters, swivel, w/o brake, Two & Three section Casters, swivel, with brake Display Door lock Legs Shelf, One Section, Three Section Shelf LH, Two Section, Three Section Shelf RH, Two Section, Three Section 5066440 3516204A Switch, rocker, door, SPDT-D8 Vacuum breaker
6000XL Series Service and Installation Manual Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
6000XL Series Service and Installation Manual Manufacturers Limited Lifetime Warranty-ABS Liner Delfield warrants to the original purchaser-user, subject to the limitations and exclusions set forth below, that the ABS interior of the Delfield models identified above will be free of manufactured defects for as long as the equipment is owned by the original purchaser-user and is in operation. What is covered.
6000XL Series Service and Installation Manual Standard One Year Warranty (One Year Parts And Labor.
Delfield ™ Mt. Pleasant, MI ® Covington, TN Thank you for choosing Delfield! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model:_______________________ S/N: _______________________ Installation Date:_______________ For a list of Delfield’s authorized parts depots, visit our website at www.delfield.com. Delfield ™ ® 980 S. Isabella Rd., Mt.