SAFE CHILL™ BLAST CHILLERS Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2.
Safe Chill™ Blast Chillers Service & Installation Manual Contents Serial Number Information RECEIVING AND INSPECTING UNIT.................................. 2 MECHANICAL DATA ............................................................. 2 INSTALLATION................................................................... 3-5 OPERATION.......................................................................... 5 CONTROL .............................................................................
Safe Chill™ Blast Chillers Service & Installation Manual Installation Location Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. Reinforce the floor if necessary to provide for maximum loading. For the most efficient operation, be sure to provide good air circulation inside and out. Inside cabinet: Do not pack the equipment so full that air cannot circulate. Outside cabinet: Be sure that the unit has access to ample air.
Safe Chill™ Blast Chillers Service & Installation Manual Safe Chill™ Control Probe Temp Box Temp OPERATION CONTINUED... Time Elapsed Time Remaining Defrost Mode: After chilling/freezing the unit will go into a defrost mode for 15 minutes or until the coil reaches a temperature of 70˚(DF1). During the freezer preservation mode the defrost heater will operate for 15 minutes (DF2) or until the coil reaches a temperature of 70˚F(DF1) every 6 hours (DF3).
Safe Chill™ Blast Chillers Service & Installation Manual OPERATION CONTINUED... 5. Start cycle with one unit running (DBC-10 only): • Press MODE button, display will change. • Press MODE button until desired mode (soft, hard, freeze) appears in left hand upper corner of display. Press START/STOP button, unit will start cycle. 6. Adjusting parameters (using this function will affect performance and should only be carried out by qualified personnel.
Safe Chill™ Blast Chillers Service & Installation Manual MAINTENANCE The interior and exterior can be cleaned using soap and warm water. If this isn’t sufficient, try ammonia and water or a nonabrasive liquid cleaner. When cleaning the exterior, always rub with the “grain” of the metal to avoid marring the finish. Do not use an abrasive cleaner because it will scratch the metal. In order to maintain proper refrigeration performance, the condenser fins must be cleaned of dust, dirt and grease regularly.
Safe Chill™ Blast Chillers Service & Installation Manual Wiring Diagram For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
Safe Chill™ Blast Chillers Service & Installation Manual 8 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
Safe Chill™ Blast Chillers Service & Installation Manual Notes: For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
Safe Chill™ Blast Chillers Service & Installation Manual Standard One Year Warranty One year service, labor and parts.
Safe Chill™ Blast Chillers Service & Installation Manual Additional Four Year Protection Plan (for Motor-Compressors only) Delfield Model# Serial # Installation Date In addition to the Standard One Year Warranty on the MotorCompressor contained in the above listed Delfield product (the “Unit”), The Delfield Company (“Delfield”) also agrees to repair, or exchange with similar or interchangeable parts in design and capacity at Delfield’s option, the defective MotorCompressor contained in the Unit (the “Mot
Delfield Authorized Parts Depots DMDBC 01/02