F5 and F15 Series Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2.
F5 & F15 Series Service and Installation Manual CONTENTS RECEIVING & INSPECTING EQUIPMENT..............................2 SPECIFICATIONS .............................................................. 3-4 INSTALLATION F15 Series......................................................................5 F5 Series........................................................................5 CONDENSER AIR FLOW Models F5 — 48” units .................................................6 Models F5 — 72” units ................
F5 & F15 Series Service and Installation Manual F5 SERIES SPECIFICATIONS MODEL NUMBER H.P.* VOLTS/HERTZ PHASE 24” (61cm) Deep Remote Drop-In Refrigerated Display Cases F5MR48N 1/2* 115/60/1 F5SR48N 1/2* 115/60/1 F5PR48N 1/2* 115/60/1 F5MR72N 3/4* 115/60/1 F5SR72N 3/4* 115/60/1 F5PR72N 3/4* 115/60/1 *Recommended horsepower MODEL NUMBER H.P. VOLTS/HERTZ PHASE AMPS AMPS EVAPORATOR CAPACITY BTU/°TD CABINET LOAD BTU/HOUR 4.0 4.0 4.0 4.0 4.0 4.
F5 & F15 Series Service and Installation Manual F15 SERIES SPECIFICATIONS MODEL NUMBER H.P.* VOLTS/HERTZ PHASE 24” (61cm) Deep Remote Serview Refrigerated Display Cases F15MR48N 3/4* 115/60/1 F15SR48N 3/4* 115/60/1 F15PR48N 3/4* 115/60/1 F15MR72N 3/4* 115/60/1 F15SR72N 3/4* 115/60/1 F15PR72N 3/4* 115/60/1 *Recommended horsepower MODEL NUMBER H.P. VOLTS/HERTZ PHASE AMPS AMPS EVAPORATOR CAPACITY BTU/°TD CABINET LOAD BTU/HOUR 4.0 4.0 4.0 4.0 4.0 4.
F5 & F15 Series Service and Installation Manual INSTALLATION: SELF-CONTAINED F15 SERIES Location Plumbing Units represented in this manual are for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded model may weigh as much as 3000 pounds! Reinforce the floor as necessary to provide for maximum loading. For the most efficient refrigeration, be sure to provide good air circulation inside and out.
F5 & F15 Series Service and Installation Manual OPERATION After turning the ON/OFF switch to ON the unit’s compressor will begin operating. Delfield display cases are designed to maintain an operational temperature of 36°F to 40°F (2°C to 4°C) in both the display (F5 and F15 Series) and storage areas (F15 Series only). Continuous opening and closing of the doors will hamper the unit’s ability to maintain operational temperatures.
F5 & F15 Series Service and Installation Manual MAINTENANCE The power must be turned off and disconnected whenever performing maintenance or repair functions. Cleaning the Condenser Coil The condenser coil requires regular cleaning, recommended is every 90 days. In some instances though you may find that there is a large amount of debris and dust or grease accumulated prior to the 90 day time frame. In these cases the condenser coil should be cleaned every 30 days.
F5 & F15 Series Service and Installation Manual Sliding Door Assembly Maintenance All Delfield F5 Series and F15 Series display cases feature a Pike® sliding door assembly. A typical Pike sliding door assembly is shown in the illustration at right. See page 11 for parts list. Frequent, regular cleaning with a mild soap and water solution will keep the tracks free of foreign matter and will insure many years of service. The glass may be cleaned with one of the many glass cleaners currently available.
F5 & F15 Series Service and Installation Manual CONDENSER AIR FLOW: 48" & 72” WIDE UNITS Unit is designed to be operated with supplied louvered panels for proper air flow. Failure to provide the proper air flow will void the warranty. An “air duct” should be constructed from the air-intake louver to the condenser. This is recommended to prevent recirculation of discharge air. Louver cut-outs are 24" by 15.5" (60.1 cm by 39.4 cm) typical. Cut-outs are to begin a maximum of 4.00" (10.
F5 & F15 Series Service and Installation Manual INSTALLATION: REMOTE F5 SERIES 1.75" 4.4cm 3.75" 9.5cm CUTOUT 3.00" x 12.00"/ 7.6cm x 30.5cm— CENTEREDFRONT TO BACK—0.25"/ R 0.6cm FROM END D C J=JUNCTION BOX R=REFRIGERATION LINES, .25" LIQUID, .37" SUCTION D=.50" I.D. DRAIN J 3.75" 9.5cm FRONT OF UNIT Typical Mechanical Access (Plan View) All F5 Models INSTALLATION: REMOTE F15 SERIES 30.00" 76.2cm 1.75" 4.4cm D 3.75" 9.5cm 1.00" 2.5cm C R D J 3.75" 9.
F5 & F15 Series Service and Installation Manual PIKE DOOR COMPONENTS 48" UNITS 72" UNITS 1. Bearing, roller, single ..........................................323-4636 2. Gasket, bumper, 31 13/16" .................................323-4808 3. Gasket, wiper strip, 30 3/8" ................................323-4809 4. Spring, 17" gold..................................................323-4810 5. Track, bottom, 43 7/16" ......................................323-4803 6. Track top, 44 7/16"........................
F5 & F15 Series Service and Installation Manual CONDENSING UNIT ASSEMBLY 9 1 72” Units 3/4 H.P. F5 48” Units 1/2 H.P. KEY 1 DELFIELD PART# DESCRIPTION 3526731 1/2 H.P. med. condensing unit 404A 3526752 welded compressor Refrigerant charges — 1/2 H.P. medium 404A — 32 oz. KEY 1 DELFIELD PART# DESCRIPTION 3526732 3/4 H.P. med. condensing unit 404A 3526753 welded compressor Refrigerant charges — 3/4 H.P. medium 404A — 48 oz.
F5 & F15 Series Service and Installation Manual FLUORESCENT LIGHT FIXTURE 7 1 KEY QTY 8 9 2 4 7 6 PRO-E PART # DESCRIPTION complete assembly, 36” XMKOO132 000-406-0037 XMKOO133 000-406-0038 complete assembly, 48” 1 1 SMK00571 221-146-0032 cap, end, top mtg, pigtail, -rem. 2 1 SMK00572 221-146-0033 cap, end, top mtg, blank, -rem. 3 1 1701046 diffuser, fluor.
F5 & F15 Series Service and Installation Manual Coil Assembly, Mullion, With Solenoid & Thermostat 5 ‡ 11 6 10 7 2 9 3 8 ‡ 4 1 KEY QUANTITY DELFIELD PART# DESCRIPTION XMK00109 complete coil assembly 1 1 PMK00036 pan, drip, evap. coil, refg. ‡ 1 AMK00012 back coil 2 2 AMK00011 side, coil, w/fan 3 2 SMK00285 bracket, mounting, fan, evap, coil 4 2 3516173 guard, fan, 6.38” dia., Lexan 5 1 3516095 coil, evap.
F5 & F15 Series Service and Installation Manual Replacement Parts List — not shown on exploded views DESCRIPTION DELFIELD PART# DESCRIPTION DELFIELD PART# Supplied on all Serviews Leg, 6” with mount plate (4 used on 48” — 6 used on 72”) . . . 3234645 Thermometer, hanging, 4” (one each in base & display) . . . . . . 3516135 Mirror Glass Mirror, glass, top, 48” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3455417 Mirror, glass, top, 72” . . . . . . . . . . . . . . . . . . . . . . . .
F5 & F15 Series Service and Installation Manual Wiring Diagram: Self-Contained F5 & F15 Series 16 For customer service, call (800) 733-8829, (800) 733-8948, Fax (989) 773-3210, www.delfield.
F5 & F15 Series Service and Installation Manual STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
F5 & F15 Series Service and Installation Manual STANDARD ONE YEAR WARRANTY (ONE YEAR SERVICE AND LABOR) The Delfield Company (“Delfield”) warrants to the Original Purchaser of the Delfield product (herein called the “Unit”) that such Unit, and all parts thereof, will be free from defects in material and workmanship under normal use and service for a period of one (1) year from the date of shipment of the Unit to the Original Purchaser or, if the Original Purchaser returns the warranty card completely fille
F5 & F15 Series Service and Installation Manual ADDITIONAL FOUR YEAR PROTECTION PLAN Delfield Model# Serial # Installation Date In addition to the Standard One Year Warranty on the Motor-Compressor contained in the above listed Delfield product (the “Unit”), The Delfield Company (“Delfield”) also agrees to repair, or exchange with similar or interchangeable parts in design and capacity at Delfield’s option, the defective Motor-Compressor contained in the Unit (the “Motor-Compressor), or any part thereof
AUTHORIZED PARTS DEPOT NORTH AMERICA 12 8 5 1 11 15 10 6 4 4 2 3 14 13 7 9 12 1) The Delfield Company 980 South Isabella Road Mt. Pleasant, MI 48858 800.733.8829 989.773.7981 989.773.3210 FAX custom parts direct from Delfield 5) Contract Ice 2) A.I.S. Commercial Parts & Service 3) Appliance Installation Service 1816 West 26th Street Erie, PA 16508-1149 800.332.3732 814.456.3732 814.452.4843 FAX 1336 Main Street Buffalo, NY 14209 800.722.1252 716.884.7425 716. 884.