Delfield ™ ® Specification Line® Installation, Use and Care Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 3.
Delfield Important Warning And Safety Information WARNING Read this manual thoroughly before operating, installing, or performing maintenance on the equipment. FAILURE TO FOLLOW INSTRUCTIONS IN THIS MANUAL CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. UNLESS ALL COVER AND ACCESS PANELS ARE IN PLACE AND PROPERLY SECURED, DO NOT OPERATE THIS EQUIPMENT. DAMP OR WET HANDS MAY STICK TO COLD SURFACES.
Specification Line Contents Serial Number........................................................................3 Receiving And Inspecting The Equipment.............................3 Model Numbers.....................................................................4 Introduction...........................................................................5 Specifications................................................................... 6-12 Installation.......................................................
Delfield S=Specification Line 4 S=Stainless interior & exterior A=Stainless exterior, aluminum interior M=Stainless front, aluminum sides and interior R=Refrigerator F=Freezer H=Heated D=Dual Temp None=Reach-in PT=Pass Thru RI=Roll-in RT=Roll Thru FF=Fish Drawers RL=Refrigerator Left FL=Freezer Left TR=Top Refrigerator BR=Bottom Refrigerator TP=Top Refrigerator Pass Thru BP=Bottom Refrigerator Pass Thru RP=Refrigerator Left Pass Thru FP=Freezer Left Pass Thru 1=1 Section 2=2 Section 3=3 Section None=
Specification Line Introduction Model numbers starting with the letters “SS” have a stainless steel exterior and interior. Model numbers starting with the letters “SA” have an aluminum interior and a stainless steel exterior. Model numbers starting with the letters “SM” have an aluminum interior and exterior with a stainless steel front and shroud. Door gaskets are magnetic and mount to the door, snapping in place and are removable without tools. Keyed door lock is mounted in the door next to the handle.
Delfield Specifications Reach-In Refrigerators - Hinged Doors - Standard Width & Depth Voltage Amps Storage Capacity Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. Shipping Weight NEMA Plug Energy (KWH) SSR1-S,SH,G,GH SAR1-S,SH,G,GH SMR1-S,SH,G,GH 115 6.0 24.96 12.81 3 1/4 2092 12.5 418lbs/ 190kg 5-15P 2.64 SSR2-S,SH,G,GH SAR2-S,SH,G,GH SMR2-S,SH,G,GH 115 9.5 51.92 27.54 6 1/3 3226 19 650lbs/ 295kg 5-15P 4.
Specification Line Specifications, continued Reach-In Refrigerators - Sliding Doors Voltage Amps Storage Capacity Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. Shipping Weight NEMA Plug Energy (KWH) SSR2-SLS,SLSH, SLG,SLGH SAR2-SLS,SLSH, SLG,SLGH SMR2-SLS,SLSH, SLG,SLGH 115 9.0 51.92 27.54 6 1/3 3226 19 670lbs/ 304kg 5-15P N/A SSR2S-SLS,SLSH, SLG,SLGH SAR2S-SLS,SLSH, SLG,SLGH SMR2S-SLS,SLSH, SLG,SLGH 115 7.8 37.96 27.54 6 1/3 2488 12.
Delfield Specifications, continued Reach-In Hot Food Cabinets - Hinged Doors - Standard Width & Depth Voltage Amps Storage Capacity Ft3 Shelf Capacity Ft2 No. Of Shelves Shipping Weight NEMA Plug Energy (KWH) SSH1-S,SH,G,GH SAH1-S,SH,G,GH SMH1-S,SH,G,GH 120/208-240 9.0 24.96 12.81 3 418lbs/190kg N/A N/A SSH2-S,SH,G,GH SAH2-S,SH,G,GH SMH2-S,SH,G,GH 120/208-240 16.0 51.92 27.54 6 650lbs/295kg N/A N/A SSH3-S,SH,G,GH SAH3-S,SH,G,GH SMH3-S,SH,G,GH 120/208-240 17.8 78.89 42.
Specification Line Specifications, continued Reach-In Freezers - Hinged Doors - Standard Width & Depth Voltage Amps Storage Capacity Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. SSF1-S,SH SAF1-S,SH SMF1-S,SH 115 9.0 24.96 12.81 3 1/2 1516 SSF1-G,GH SAF1-G,GH SMF1-G,GH 115 11.5 24.96 12.81 3 3/4 SSF2-S,SH SAF2-S,SH SMF2-S,SH 115 14.3 51.92 27.54 6 SSF2-G,GH SAF2-G,GH SMF2-G,GH 115/ 208-230 10.0 51.92 27.
Delfield Specifications, continued Pass-Thru Refrigerators - Hinged Doors - Standard Width Voltage Amps Storage Capacity Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. Shipping Weight NEMA Plug Energy (KWH) SSRPT1-S,SH SARPT1-S,SH SMRPT1-S,SH 115 6.8 26.64 12.81 3 1/4 2092 12.5 455lbs/ 206kg 5-15P 3.14 SSRPT1-G,GH SARPT1-G,GH SMRPT1-G,GH 115 7.8 26.64 12.81 3 1/3 2488 12.5 455lbs/ 206kg 5-15P 4.58 SSRPT2-S,SH SARPT2-S,SH SMRPT2-S,SH 115 16.0 55.
Specification Line Specifications, continued Fish Drawer Reach-In - Four Fish Drawers Per Section Voltage Amps Storage Capacity Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. Shipping Weight NEMA Plug Energy (KWH) SSRFF1 115 6.8 24.96 N/A N/A 1/4 2092 12.5 418lbs/ 190kg 5-15P N/A SSRFF2 115 9.0 51.92 N/A N/A 1/3 3226 19 650lbs/ 295kg 5-15P N/A Voltage Amps Storage Capacity Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz.
Delfield Specifications, continued Roll-In Freezers Voltage Amps Storage Capacity Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. Shipping Weight NEMA Plug Energy (KWH) SSFRI1-S SAFRI1-S SMFRI1-S 115 7.8 36.15 N/A N/A 1/2 1516 12.5 497lbs/ 225kg 5-15p 11.57 SSFRI2-S SAFRI2-S SMFRI2-S 115/ 208-230 10.0 74.12 N/A N/A 1 4793 30 824lbs/ 374kg N/A 21.02 SSFRI3-S SAFRI3-S SMFRI3-S 115/ 208-230 11.8 113.
Specification Line Installation Location Stabilizing Cabinets represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet, 1000 pounds. per door section. Reinforce the floor if necessary to provide for maximum loading. For the most efficient operation, be sure to provide good air circulation inside and out. The location should be selected so that the power cord can be connected without any extensions.
Delfield Installation, continued Electrical Connection Refer to the amperage data list in the SPECIFICATIONS or the serial tag data and your local code or the National Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be run for connection of the supply cord or permanent connection to the unit. The power must be turned off and disconnected whenever performing maintenance or repair functions.
Specification Line Electronic Temperature Control Operation The electronic temperature control constantly monitors box temperature as well as evaporator coil temperature to maintain consistent product temperatures. The control also sends temperature readings to the digital temperature display. The control circuits continually self-check and if an error occurs, the digital display will switch from temperature read-out to error read-out, i.e. E1.
Delfield Electronic Temperature Control Operation, continued Regarding Single Section Dual Temperature Units: After initializing, the both controls will immediately enter a DEFROST mode and the displays will read DEF. The compressor and condenser fan as well as the evaporator fan will remain off until initialization defrost is complete. This initial defrost cycle may take up to 15 minutes to complete, at which time the freezing cycle will begin.
Specification Line Door Reversal Procedures Only for Models Ordered With Re-Hinging Option. The re-hinging option is only available on solid door models. 1. Lift front shroud if re-hinging the control side. If re-hinging the rear side, the shroud must be removed. 2. Open door 90˚ and lift door straight up and off hinges. 3. Remove the metal screw covers on each door-side hinge section by sliding it down and off. 4.
Delfield Heated Cabinet Operation The Heated units have a POWER ON/OFF switch located behind the flip up shroud at the front top of the unit for controlling power to the unit and an electronic thermostat for setting the temperature. A circulating fan provides uniform airflow in the cabinet. Power Up 1. 2. 3. 4. 5. 18 Check that unit is properly connected to the power source. Raise the shroud to access the controls. Set the Main POWER ON/OFF switch, to the ON position.
Specification Line Maintenance Door Gasket Maintenance Door gaskets require regular cleaning to prevent mold and mildew build up and also to retain the elasticity of the gasket. Gasket cleaning can be done with the use of warm soapy water. Avoid full strength cleaning products on gaskets as this can cause them to become brittle and crack. Never use sharp tools or knives to scrape or clean the gasket. Gaskets can be easily replaced and do not require the use of tools or an authorized service person.
Delfield Maintenance, continued and preserve the finish of the steels protective layer. Early signs of stainless steel breakdown are small pits and cracks. If this has begun, clean thoroughly and start to apply stainless steel cleaners in attempt to restore the passivity of the steel. Never use an acid based cleaning solution! Many food products have an acidic content, which can deteriorate the finish. Be sure to clean the stainless steel surfaces of ALL food products.
Specification Line REVISIONS REV Wiring Diagram Specification Line Refrigerators S_R1, S_R1N, S_R1S, S_RPT1, S_RPT1S, 9294455 L1 S_RRI1,11"S_RRT1, 17-MAY-2011 L ENNIS BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY) 26-MAY-2011 L ENNIS 3 M Y N 5 BLUE F M 6 FAN RELAY PLUG DEFROST HEATER EVAP COIL SENSOR CONTROL CIRCUIT W EVAPORATOR FAN INCANDESCENT LIGHT H 4 HEATER RELAY C M W CONTROL BOX 1 COMPRESSOR RELAY COMPRESSOR ENERGY SAVER SWITCH W WITH BLUE STRIPES WIRE NUT W P 1.
Delfield REVISIONS REV Wiring Diagram Specification Line Refrigerators DATE APPROVED 1 INITIAL RELEASE DESCRIPTION 2 ADDED L-2/3 DESIGNATION & H-4 FOR HEATER TERMINAL 17-MAY-2011 L ENNIS 3 BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY) 26-MAY-2011 L ENNIS 11" S_R2, S_R2N, S_R2S, S_R2-SL, S_R2S-SL, S_RPT2S, S_RRI2, SSRFF2 - Solid Doors 9294454 L1 NOTES: 1) USE COPPER CONDUCTORS ONLY 2) THIS UNIT MUST BE GROUNDED 3) UNIT SHOWN WITH COMPRESSOR RUNNING AND DOORS CLOSED N LINE VOLTAGE 115/
Specification Line REVISIONS REV Wiring Diagram Specification Line Refrigerators S_RPT2, S_RRT2 - Solid Doors S_R3, S_RPT3, S_RRI3 - Solid Doors 9294479 L1 L ENNIS 2 ADDED L-2/3 DESIGNATION & H-4 FOR HEATER TERMINAL 17-MAY-2011 L ENNIS 3 BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY) 26-MAY-2011 L ENNIS M Y N 5 BLUE F M 6 FAN RELAY PLUG W EVAP COIL SENSOR CONTROL CIRCUIT EVAPORATOR FAN INCANDESCENT LIGHT H 4 HEATER RELAY C M W WITH BLUE STRIPES W CONTROL BOX 1 COMPRESSOR REL
Delfield Wiring Diagram Specification Line Refrigerators S_RRT3 - Solid Doors Wiring Diagram Specification Line Freezers S_F1, S_F1N, S_F1S - Solid Doors 24
Specification Line Wiring Diagram Specification Line Freezers S_F1 - Glass Doors S_FPT1, S_FRI1 - Solid Doors 25
Delfield Wiring Diagram Specification Line Freezers S_F2, S_F2N, S_F2S - Solid Doors S_F2, S_F3 - Glass Doors 26
Specification Line Wiring Diagram Specification Line Freezers S_FPT2, S_FRI2, S_F3, S_FRI3 - Solid Doors S_FPT3 - Solid Doors 27
Delfield Wiring Diagram Specification Line Heated Models S_H1, S_H2, S_H3, S_HRI1, S_HRI2, S_HRI3 - Solid & Glass Doors S_H2N, S_HPT1, S_HPT2, S_HRT1, S_HRT2, S_HRT3 - Solid Doors Wiring Diagram Specification Line Refrigerator/Freezer Combinations S_DTR1, S_DBR1 - Solid & Glass Doors 28
Specification Line Compressor Diagrams Capacitor, start Relay & Overload Valve, EXP Compressor Drier, filter Motor, fan, evaporator Motor, fan, condensor Blade, fan Guard, fan, condenser Coil, condenser Coil, evaporator Fan delay, defrost limit Blade, fan, condenser Guard, fan, condenser Coil, evaporator Coil, condenser Valve, EXP Motor, fan, evaporator Compressor Relay & Overload Blade, fan Capacitor, start Fan delay, defrost limit Heater, defrost Switch Control switch Drier, filter 29
Delfield Replacement Parts S_R1, S_R1N, S_R1S, S_RPT1, S_RPT1S, S_DRL2, S_DFL2, S_DRP2, S_DFP2 - Solid Doors S_R1, S_R1N, S_R1S, S_DRL2, S_DFL2 - Glass Doors S_R2S, S_R2S-SL, S_RRT1 - Solid Doors S_R2S, S_R2S-SL, S_RPT1, S_RRI1 - Glass Doors Part Number Description Part Number Description 2194792 Display, Blue, Danfoss 2194792 Display, Blue, Danfoss 3516433 Blade, Fan, 25 3516432 Blade, Fan, 25Deg, 8.75" 3517390 Blade, Fan, 5.56, CW, Lexan 3517390 Blade, Fan, 5.
Specification Line Replacement Parts, continued S_RRI3 - Glass Doors Part Number Description 3517390 Blade, Fan, 5.56, CW, Lexan 3516308 Coil, Evap, R-404A 3526906 Cond Unit, FJEF-A075-CAV 2194782KT Control, Danfoss, 115V 3516227 Drier, Filter, 5 CU. IN. 000-BAB-0033 Kit, Ref.
Delfield Replacement Parts, continued S_F3, S_FPT2, S_FRI2 - Solid Doors S_F2 - Glass Doors S_F2S, S_DRP2, S_DFP2 - Solid Doors S_F1 - Glass Doors Part Number Description Part Number Description 3516433 Blade, Fan, 25 3516433 Blade, Fan, 25 3516204A 3517390 Blade, Fan, 5.
Specification Line Replacement Parts, continued S_DTR1, S_DBR1 - Solid & Glass Doors S_DTP1, S_DBP1 - Solid & Glass Doors Part Number Description Part Number Description 3516172 Blade, Fan, 5.56, CCW 3516172 Blade, Fan, 5.56, CCW 3516432 Blade, Fan, 25deg, 8.75", Cw 3516239 Coil, Evap, Dough, RT, Spec 3516427 Coil, Condenser, Large, Upright 3516220 Coil, Evap, Frz, RT, Spec 3516239 Coil, Evap, Refrig.
Delfield Shelf Replacement Parts Model Shelf Number S_R1-S,SH,G,GH S_RPT1-S,SH S_RPT1S-S,SH S_DRL2-S,SH,G,GH S_DFL2-S,SH,G,GH S_DRP2-S,SH, S_DFP2-S,SH S_R2-SLS,SLSH,SLG,SLGH S_RPT1-G,GH S_R3-S,SH,G,GH S_RPT2-S,SH S_RPT2-G,GH S_RPT3-S,SH S_RPT3-G,GH S_F1-S,SH S_F2-S,SH S_F2-G,GH S_F3-S,SH S_FPT2-S,SH S_F3-G,GH S_F1-G,GH S_FPT1-S,SH S_FPT3-S,SH 3978170 S_H1-S,SH,G,GH S_H2-S,SH,G,GH S_HPT1-S,SH S_HPT2-S,SH 3978171 S_R1N-S,SH,G,GH S_R2N-S,SH,G,GH S_F1N-S,SH S_F2N-S,SH 3978172 S_H2N-S,SH 3978173 S_R1S
Specification Line Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
Delfield Standard Two Year Warranty (Two year parts and labor, five year compressor) The Delfield Company (“Delfield”) warrants to the Original Purchaser of the Delfield product (herein called the “Unit”) that such Unit, and all parts thereof, will be free from defects in material and workmanship under normal use and service for a period of two (2) years from the date of shipment of the Unit to the Original Purchaser or, if the Original Purchaser returns the warranty card completely filled out including th
Specification Line Additional Three Year Protection Plan (for motor-compressor only) In addition to the Standard Two Year Warranty on the Motor Compressor contained in the above listed Delfield product (the “Unit”), The Delfield Company (“Delfield”) also agrees to repair, or exchange with similar or interchangeable parts in design and capacity at Delfield’s option, the defective MotorCompressor contained in the Unit (the “Motor-Compressor), or any part thereof, for the Original Purchaser only, at any time
Delfield Notes 38
Specification Line Notes 39
Delfield ™ Mt. Pleasant, MI ® Covington, TN Thank you for choosing Delfield! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model:_____________________ S/N: ____________________ Installation Date:_____________ For a list of Delfield’s authorized parts depots, visit our website at www.delfield.com. Delfield ™ ® 980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.