Deployment Guide

28 Deployment Guide
155.16.170.201rac1-vip
155.16.170.202rac2-vip
NOTE: Registering the private IP addresses with the DNS server is not
required as the private network IP addresses are not accessible from the
public network.
5
Repeat step 1 through step 4 on the remaining nodes.
6
Ensure that the cluster nodes can communicate with the public and
private networks.
a
On node 1, open a command prompt window.
b
At the command prompt, enter:
ping <
public_host_name
>
ping <
private_host_name
>
where <
public_host_name
> and <
private_host_name
> are the host
names for the public and private network adapters in the remaining
node.
If the node’s network adapters do not respond to ping commands,
check your network configuration and then repeat this step.
NOTE: Virtual internet protocol (VIP) is configured later and cannot be pinged
at this point.
c
Repeat step a through step b on the remaining nodes.
Installing the Host-Based Software Needed for Storage
To install the EMC Naviagent software using the EMC software that came
with your Dell|EMC system, follow the procedures in your Dell|EMC
documentation.
To install the necessary host-based storage software for the PowerVault
MD3000 storage system, use the Dell PowerVault Resource CD software that
came with your MD3000 storage system. Follow the procedures in your Dell
documentation that is included with the PowerVault MD3000 storage system
to install the "Modular Disk Storage Manager Software" on the Master node
and the Multi-Path (MPIO) software on the remaining nodes.