Datasheet

PowerEdge T410 Technical Guidebook
23
Dell
Table 6. T410 ePPID Descriptions and Locations
COMPONENT DESCRIPTION STORAGE LOCATION
Planar PWA, PLN, SV, DELL, R410 iDRAC FRU
4" x 2.5" Backplane PWA, BKPLN, SV, R410, 2.5SASX4 SEP
4" x 3.5" Backplane PWA, BKPLN, SV, R410, 3.5SASX4 SEP
500W T410 Rdnt PSU
PWR SPLY,500W,RDNT, DELTA PSU Microcontroller
PWR SPLY,500W,RDNT,EMERSON PSU Microcontroller
T410 PDB ASSY,PWA,PDB,R410 Microcontroller
Storage Card Description Storage Location
PERC 6/I Adapter ASSY, CRD, PERC6I-ADPT, SAS FRU
PERC 6/E External PWA, CTL, PCIE, SAS, PERC6/E,ADPT FRU
SAS 6/iR integrated PWA, CTL, SAS, SAS6/IR, INTG FRU
6 Power, Thermal, and Acoustic
6.1 Power Supplies
The standard PowerEdge T410 tower server includes a single 525 W power supply. This power supply
unit provides power to the T410 planar, the four internal hard drive bays, and the two 5.25” external
drive bays. The T410’s power is soft-switched, allowing power cycling via a switch on the front of the
system enclosure or via a software control (through server management functions). This power system
is compatible with industry standards, such as ACPI and Server 2000.
The T410 is powered by the standard non-redundant 525 W (Dell P/N C488 K) power supply or by two
redundant 580 W (Dell P/N D888J) power supplies with PDB (power distribution board, Dell P/N
M720J).
Figure 27 shows the 525W non-redundant PSU (Dell P/N C488 K), Figure 28 show the 580 W
redundant PSU (Dell P/N D888J), Figure 29 shows the PDB (power distribution board, Dell P/N
M720J).
Figure 27. Rear ISO View of Non-redundant PSU (Dell P/N C488 K)