Installation Guide

Table Of Contents
Table 2. N3200-ON Series switch LED behavior (continued)
LED Description
Power LED
OffNo power
Solid GreenNormal operation
Solid yellowPOST is in process
Flashing yellowPower supply failed
FAN LED
OffNo power
Solid greenNormal operation; fan powered and running
at the expected RPM
Flashing yellowFan faultincluding incompatible airflow
direction when you insert the PSU, fan trays with differing
airflows, missing a fan, or fan tray not functioning properly
Locator LED/System Beacon
OffLocator function disabled
Flashing blueLocator function enabled
Table 3. 1000MBase-T and 10/100MBase-T PoE System management Ethernet port LEDs
LED Description
Link LED
OffNo link
Solid greenLink operating at a maximum speed,
autonegotiated/forced to 1000MBase-T mode
Solid yellowLink operating at a lower speed,
autonegotiated/forced or 10/100MBase-T mode
Activity LED
OffNo activity
Solid YellowNo port activity and PoE power on
Flashing greenPort activity and PoE power off
Flashing yellowPort activity and PoE power on
Table 4. 1000MBase-T and 10/100MBase-T non-PoE System management Ethernet port LEDs
LED Description
Link LED
OffNo link
Solid greenLink operating at a maximum speed,
autonegotiated/forced to 1000MBase-T mode
Solid yellowLink operating at a lower speed,
autonegotiated/forced or 10/100MBase-T mode
Activity LED
OffNo activity
Flashing greenPort activity
Table 5. 1G, 5G, 10G Base-T PoE port LEDs
LED Description
Link LED All four LEDs:
OffNo link
Solid greenLink operating at maximum speed,
autonegotiated/forced to 2.5GBase-T mode
Solid yellowLink operating at a lower speed,
autonegotiated/forced to 10/100/1000MBase-T
Flashing green, ~30msPort activity
Activity LED
OffNo activity and PoE power off
Solid yellowNo port activity and PoE power on
16 N3200-ON Series switch