Table 12. Chassis physical design (continued)
Parameter Specifications
Rack clearance required
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Table 13. Environmental parameters
Parameter Specifications
Operating temperature 32°F to 113°F (0°C to 45°C) continuously
NOTE: Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 ft).
Operating humidity 5% to 95% (RH), noncondensing
Storage temperature 40°F to 158°F (40°C to 70°C)
Storage humidity 5% to 95%, noncondensing
Maximum thermal output
N3208PX-ON: 49.48 W = 168.83 BTU/Hr
N3224T-ON: 95.58 W = 326.13 BTU/Hr
N3224F-ON: 122.08 W = 416.55 BTU/Hr
N3224P-ON: 100.74 W = 343.74 BTU/Hr
N3224PX-ON: 173.01 W = 590.33 BTU/Hr
N3248TE-ON: 102.3 W = 349.06 BTU/Hr
N3248X-ON: 300.06 W = 1023.85 BTU/Hr
N3248P-ON: 112.26 W = 383.05 BTU/Hr
N3248PXE-ON: 325.72 W = 1111.40 BTU/Hr
Maximum operational altitude 10,000 feet (3,048 m)
Maximum non-operational altitude 39,370 feet (12,000 meters)
Shock Dell EMC Spec SV0115
Table 14. Power consumption parameters
Parameter Specifications
Minimum and maximum Input voltage
NOTE: For more information, see Power supplies.
AC: 100240 VAC 50/60 Hz
DC: 40 VDC to 60 VDC
Input current without PoE
N3208PX-ON: 1.12 Amps @ 110 VAC and 0.56 Amps @
220 VAC
N3224T-ON: 2.08 Amps @ 110 VAC and 1.04 Amps @ 220
VAC
N3224F-ON: 2.32 Amps @ 110 VAC and 1.16 Amps @ 220
VAC
N3224P-ON: 2.26 Amps @ 110 VAC and 1.13 Amps @ 220
VAC
N3224PX-ON: 3.44 Amps @ 110 VAC and 1.72 Amps @
220 VAC
N3248TE-ON: 2.22 AMps @ 110 VAC and 1.11 Amps @ 220
VAC
N3248P-ON: 2.4 Amps @ 110 VAC and 1.2 Amps @ 220
VAC
N3248X-ON: 4.9 Amps @ 110 VAC and 2.5 Amps @ 220
VAC
N3248PXE-ON: 5.44 Amps @ 110 VAC and 1.72 Amps @
220 VAC
PSU configuration Main PSU