Table 2. N2200-ON Series switch LED behavior
LED Description
7-Segment LED for stacking
Off—No power
Solid green—Hex digit representing the stack unit ID
Stack Master LED
Off—Switch is in Stacking Slave mode
Solid green—Switch is in Stacking Master or Standalone mode
System Status/Health LED
Solid green—Normal operation
Flashing green—Booting
Solid yellow—Critical system error; major fault
Flashing yellow—Noncritical system error, minor fault, fan
failure, or power supply failure
Power LED
Off—No power
Solid Green—Normal operation
Solid yellow—POST is in process
Flashing yellow—Power supply failed
FAN LED
Off—No power
Solid green—Normal operation; fan powered and running at the
expected RPM
Flashing yellow—Fan fault—including incompatible airflow
direction when you insert the PSU, fan trays with differing
airflows, missing a fan, or fan tray not functioning properly
LOCATOR LED/System Beacon
Off—Locator function disabled
Flashing blue—Locator function enabled
Table 3. 1000MBase-T and 10/100MBase-T PoE System management Ethernet port LEDs
LED Description
Link LED
Off—No link
Solid green—Link operating at a maximum speed,
autonegotiated/forced to 1000MBase-T mode
Solid yellow—Link operating at a lower speed, autonegotiated/
forced or 10/100MBase-T mode
Activity LED
Off—No activity
Solid Yellow—No port activity and PoE power on
Flashing green—Port activity and PoE power off
Flashing yellow—Port activity and PoE power on
Table 4. 1000MBase-T and 10/100MBase-T non-PoE System management Ethernet port LEDs
LED Description
Link LED
Off—No link
Solid green—Link operating at a maximum speed,
autonegotiated/forced to 1000MBase-T mode
Solid yellow—Link operating at a lower speed, autonegotiated/
forced or 10/100MBase-T mode
Activity LED
Off—No activity
Flashing green—Port activity
12 N2200-ON Series switch