Installation Guide

Table Of Contents
Specifications
This section lists the N2200-ON Series switch specifications.
CAUTION: Operate the product at an ambient temperature not higher than 45°C (113°F).
NOTE: For RoHS information, see Restricted Material Compliance.
Topics:
Chassis physical design
IEEE standards
Agency compliance
Chassis physical design
Table 10. Chassis physical design
Parameter Specifications
Height x Width x Depth measurements, excluding the PSU and fan
tray handle
1.71 in x 17 in x 15.75 in (H x W x D)
43.5 mm x 434 mm x 400 mm (H x W x D)
(PSU and fan tray handle adds 1.18 in or 30 mm)
Chassis weight with one PSU installed
N2224X-ON: 14.30 lbs (6.485 kg)—PSU is 1.75 lbs, 0.79 kg
(550W)
N2224PX-ON: 14.70 lbs (6.67 kg)—PSU is 1.95 lbs, 0.88 kg
(1050W)
N2248X-ON: 15.09 lbs (6.845 kg)—PSU is 1.75 lbs, 0.79 kg
(550W)
N2248PX-ON: 15.77 lbs (7.155 kg)—PSU is 2.0 lbs, 0.90 kg
(1600W)
Rack clearance required
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Table 11. Environmental parameters
Parameter Specifications
Operating temperature 0° to 45°C (32°F to 113°F) continuously
NOTE: Reduce maximum temperature by 1°C/125
meters (1°F/228 feet) above 950 meters (3,117 feet).
Operating humidity 5% to 95% (RH), non-condensing
Storage temperature –40° to 70°C (–40° to 158°F )
Storage humidity 5% to 95%, non-condensing
Maximum thermal output without PoE
N2224X-ON: 105 W = 811.58 BTU/hr
N2224PX-ON: 115 W = 811.58 BTU/hr
N2248X-ON: 160 W = 1111.66 BTU/hr
N2248PX-ON: 170 W = 1111.66 BTU/hr
Maximum operational altitude 10,000 feet (3,048 meters)
9
54 Specifications