Users Guide

tion
pdmAudio pdmAudioVolume .1.3.6.1.4.1.2699.2.4.1.16.2.0 Integer R/W
pdmAudio pdmAudioMute .1.3.6.1.4.1.2699.2.4.1.16.3.0 Integer R/W
pdmAudio pdmAudioTreble .1.3.6.1.4.1.2699.2.4.1.16.4.0 Integer R DEFVAL { 0 }
pdmAudio pdmAudioBass .1.3.6.1.4.1.2699.2.4.1.16.5.0 Integer R DEFVAL { 0 }
pdmAudio pdmAudioBalance .1.3.6.1.4.1.2699.2.4.1.16.6.0 Integer R DEFVAL { 0 }
pdmAlert pdmAlertIndex 1.3.6.1.4.1.2699.2.4.1.18.1.1.1.1 Integer not-accessible 1
pdmAlert
pdmAlertGroupTy
pe
1.3.6.1.4.1.2699.2.4.1.18.1.1.2.1 String R See Note 1
pdmAlert pdmAlertGroupId 1.3.6.1.4.1.2699.2.4.1.18.1.1.3.1 String R See Note 1
pdmAlert pdmAlertCode 1.3.6.1.4.1.2699.2.4.1.18.1.1.4.1 String R DEFVAL { "" }
pdmAlert
pdmAlertDescripti
on
1.3.6.1.4.1.2699.2.4.1.18.1.1.5.1 String R
Alert's condition has lamp Fail,
Lamp hours running out,
Projector Overheating, Lamp
Overheating and Fan Error.
pdmAlert
pdmAlertSeverityL
evel
1.3.6.1.4.1.2699.2.4.1.18.1.1.6.1 Integer R See Note 1
pdmAlert
pdmAlertTraining
Level
1.3.6.1.4.1.2699.2.4.1.18.1.1.7.1 Integer R DEFVAL { 2 }
pdmAlert
pdmAlertDateTim
e
1.3.6.1.4.1.2699.2.4.1.18.1.1.8.1 String R
DEFVAL
{ "1980-01-01T00:00:00" }
pdmAlert
pdmAlertPowerOn
Count
1.3.6.1.4.1.2699.2.4.1.18.1.1.9.1 String R DEFVAL { "" }
pdmAlert
pdmAlertSysUpti
me
1.3.6.1.4.1.2699.2.4.1.18.1.1.10.1 String R DEFVAL { "" }
pdmAlert
pdmAlertCriticalA
lertsCount
1.3.6.1.4.1.2699.2.4.1.18.2.0 Integer R
pdmAlert
pdmAlertAllAlerts
Count
1.3.6.1.4.1.2699.2.4.1.18.3.0 Integer R
Note 1:
a) If there is no any current alert, all of OID in alert table will respond default value.
pdmAlertGroupType =”
pdmAlertGroupID = 0
pdmAlertSeverity = other (1)
The reset Object will respond default.
b) If there is FAN alert happen, the tables is shown below.
pdmAlertGroupType =” Fan”
pdmAlertGroupID =Fan Error
pdmAlertSeverity = Critical (3)
The rest Object will respond default.
c) If there is Lamp fail alert happen, the tables is shown below.
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp Fail
pdmAlertSeverity = Critical (3)
The rest Object will respond default.
d) If there is Lamp hours running out alert happen, the tables is shown below.
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp hours running out
pdmAlertSeverity = warning (4)
The rest Object will respond default.
e) If there is Projector Over-heating alert, the tables is shown below.
pdmAlertGroupType = “ThermalSensor”
pdmAlertGroupID= “Projector Overheating”
pdmAlertSeverity = warning (4)
The rest Object will respond default.
f) If there is Lamp Over-heating alert, the tables is shown below.
pdmAlertGroupType = “ThermalSwitch”
pdmAlertGroupID=Lamp Overheating
pdmAlertSeverity = Critical (3)
The rest Object will respond default.
Information in this document is subject to change without notice.
© 2012 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.