Setup Guide

Specification Prerequisite
Dell PowerEdge M I/O Aggregator
Server facing ports must be in switchport
mode.
Server facing ports must be configured for
spanning tree portfast.
If ASM is used to do the initial configuration of
credentials and IPs on the IOM in the blade
chassis, you need to make sure, no enabled
password is configured on the switches.
Dell Networking MXL 10/40GbE blade switch
Any VLAN which is dynamically provisioned by
ASM must exist on the switch.
Server facing ports must be configured for
spanning tree portfast.
Make sure DCB settings are configured on each
port.
If ASM is used to do the initial configuration of
credentials and IPs on the IOM in the blade
chassis, you need to make sure, no enabled
password is configured on the switches.
Switches have SSH connectivity enabled.
Dell 8 | 4 I/O modules
The management IP address is configured for
the Brocade switches.
Brocade switch should be only in Access
Gateway Mode.
EqualLogic Storage Array
The management and group IP addresses are
configured for Storage Array.
All storage array members are added to the
group.
NOTE: The Equallogic management
interface must be configured to enable
dedicated management network.
EqualLogic array must have a SNMP community
name set to "public".
Compellent Storage Array
The management IP address is configured for
Storage Array
All storage array members are added to the
group.
Virtual ports must be enabled on compellent.
Follow Compellent best-practices for storage
configuration.
Storage Centers needs to be added to the
Enterprise Manager before initiating the
Element Manager discovery in ASM
Fault Domain and IP Address configuration of
iSCSI controllers needs to be done before
discovery Element Manager in ASM
12