Users Guide

For configuring interface on the Blade Servers, see Configuring Interface on Blade Servers
10. Click Add.
NOTE: PowerEdge C6220 server and FX2 server are newly added resource.
NOTE: For C-Series server: Hardware monitoring is not available for DellPowerEdge C 6220 Server,
whereas it is available for iDRAC-based server. Network and BIOS configuration cannot be
performed using appliance. You need to do it manually. You need to make sure that hard disk is
available for server to install OS. You need to set single NIC to PXE boot. This should be set as first
boot device and hard disk should be set as second boot device.
You need to configure network on top of rack switch which are connected to C-Series server. You
need to configure necessary VLAN on the service facing port of that top of rack switch. For that you
need to place PXE VLAN-untagged for any kind of OS deployment. If it’s Windows and Linux bare
metal OS installation, you need to set worklaod network and you need to set Hypervisor
management network for ESXi deployment.
NOTE: For FX Server : FX2 Server is very similar to M1000E chassis. FX2 is kind of a chassis but it’s
smaller than usual chassis. It’s only support four servers. It only support fabric A network support,
whereas M1000E Chassis support Fabric A, Fabic, Fabric C. Apart from Fabric A, FX2 supports PCI
card.
Server settings
Target Boot Device Description
Hardware Settings
Target Boot Device Specifies the target boot device ( for example: Local Hard Drive or SD
card).
RAID You can configure RAID using this feature. Two options are there two
configure RAID Level:
Basic RAID Level
Advanced RAID Configuration
Basic RAID Level: Select Basic RAID Level option, and then select RAID
level from the Basic RAID Level drop-down menu.
Advanced RAID Configuration: If you want to perform advance RAID
Configuration, select Advanced RAID Configuration option. After you
select Advanced RAID Configuration, Enable Global Hotspares check
box and Add Virtual Disk tab appear.
Enable Global Hotspares : To enable hotspare select Enable Global
Hotspares checkbox. You can specify the number of hotspare you
want set for SSD type disk.
Add Virtual Disk : Click Add Virtual Disk tab to add virtual disk. After
you click Add Virtual Disk tab, you must select RAID level from
Advance Configuration drop-down menu and specify number of disk
from # of Disks drop down menu. You can select minimum number
of disk or exact number of disk. To select multiple number of disk,
click again Add Virtual Disk and repeat the same steps.
System Profile Select the system power and performance profile for the server.
54