Install Guide

Specification Pre-requisite
Follow Dell Compellent best-practices for storage configuration.
Storage Centers needs to be added to the Enterprise Manager before initiating the Element
Manager discovery in ASM.
Fault Domain and IP Address configuration of iSCSI controllers needs to be done before
discovery Element Manager in ASM.
Discovery of EM needs to be done with same credentials which are used for add storage
center in Element Manager.
Enable SNMP on Dell Compellent to enable ASM to monitor the device.
For more information on creating alias, see Brocade for Dell Compellent section in this
topic.
Dell Compellent iSCSI on MXL
with Hyper V
Enable LLDP and its corresponding attributes.
DCB (with no PFC option) on the participating interfaces (Server Facing and Port-Channel
Members). Since DCB is globally enabled, the PFC should be turned off individually in those
interfaces.
Link Level Flow control (LLFC) must be Rx ON and Tx OFF on the respective interfaces.
MTU must be set to 9216 on respective interfaces.
Sample server facing interface configuration
FTOSA1#show running-config interface tengigabitethernet 0/15
!
interface TenGigabitEthernet 0/15
no ip address
mtu 9216
portmode hybrid
switchport
flowcontrol rx on tx off
spanning-tree 0 portfast
spanning-tree pvst edge-port
dcb-map DCB_MAP_PFC_OFF
!
protocol lldp
advertise management-tlv management-address system-name
dcbx port-role auto-downstream
no shutdown
Sample port-channel member interface configuration
FTOSA1#show running-config interface tengigabitethernet 0/41
!