Install Guide

Specification Pre-requisite
interface TenGigabitEthernet 0/41
no ip address
mtu 9216
dcb-map DCB_MAP_PFC_OFF
!
port-channel-protocol LACP
port-channel 1 mode active
!
protocol lldp
advertise management-tlv management-address system-name
no advertise dcbx-tlv ets-reco
dcbx port-role auto-upstream
no shutdown
FTOSA1#
VMware vCenter 5.1, 5.5 or 6.0
VMware vCenter 5.1, 5.5 or 6.0 is configured and accessible through the management and
hypervisor management network.
Appropriate licenses are deployed on the VMware vCenter.
System Center Virtual Machine
Manager (SCVMM)
See System Center Virtual Machine Manager (SCVMM) Prerequisites.
OS Installation
Either use Active System Manager as the PXE responder by configuring through ASM user
interface, by Getting Started page or follow instructions in Configuring ASM Virtual
Appliance as PXE Responder.
Dell PowerEdge M1000e chassis
NOTE: Prior to deployment of M1000e server, you need to disable FlexAddress every
server in the chassis.
To disable FlexAddress, follow the path:CMC > Server Overview > Setup > FlexAddress.
You need to turn off server to disable FlexAddress. This should be done prior discovering
the server.
This setting applies to the chassis and the servers in the chassis, not to the IOM switches
such as MXL or IOA.
Dell PowerEdge FX2 chassis
NOTE: Prior to deployment of FX2 server, you need to disable FlexAddress every
server in the chassis.
To disable FlexAddress, follow the path: CMC > Server Overview > Setup >
FlexAddress.
You need to turn off server to disable FlexAddress. This should be done prior discovering
the server.
This setting applies to the chassis and the servers in the chassis, not to the IOM switches
such as MXL or IOA.
13