Reference Guide

Table Of Contents
For Location, enter the shared path location: \\<servername\folder\filename.xml>.
For Credentials, create a credentials profile or use an existing profile to connect to the shared path.
c. Click Test Connection to test the connection to the shared path.
d. Click Save.
Updating the firmware on a bare-metal server
With OpenManage Integration for Microsoft System Center on a bare-metal server, you can update firmware or schedule
firmware updates.
Steps
1. Launch SCVMM.
2. In the left pane, click Fabric, and then, under Servers, select All Hosts.
3. On the top banner, click DELL EMC OMIMSSC.
4. In the left pane, select Maintenance Center.
5. In the Device Group/Servers list, select Default Unassigned Servers Update Group, which is where the discovered
servers are listed.
6. Under Select Update Source, select DELL ONLINE HTTPS S2D CATALOG.
Use the Filter Updates menu to filter the compliance report based on the nature of the update, component type, or server
model.
The compliance report of the servers in the selected group is displayed.
7. Click Run Update.
8. In the Update Details window:
At Firmware Update Job Name, enter the job name.
At Firmware Update Job Description, enter the job description.
If you want to downgrade the firmware to the catalog version (not recommended), select Allow Downgrade.
At Schedule Update, select Run Now or schedule an update for a later time.
At Update Method, select an update method.
Agent Free UpdateUpdates are applied, and the system restarts immediately.
Agent-Free Staged UpdateUpdates that do not require a system restart are applied immediately. Updates that
require a restart are applied when the system restarts.
9. Click Finish.
Updating the firmware with the cluster-aware feature
With OpenManage Integration for Microsoft System Center, you can update firmware or schedule firmware updates using the
cluster-aware feature.
Steps
1. Launch SCVMM.
2. In the left pane, click Fabric, and then, under Servers, select All Hosts.
3. On the top banner, click DELL EMC OMIMSSC.
4. In the left pane, select Maintenance Center.
5. In the Device Group/Servers list, select Cluster_
<ClusterName>
_Group, which is where the discovered servers are
listed.
6. Under Select Update Source, select DELL ONLINE HTTPS S2D CATALOG.
Use the Filter Updates menu to filter the compliance report based on the nature of the update, component type, or server
model.
The compliance report of the servers in the selected group is displayed.
7. Click Run Update.
8. In the Update Details window:
At Firmware Update Job Name, enter the job name.
At Firmware Update Job Description, enter the job description.
If you want to downgrade the firmware to the catalog version (not recommended), select Allow Downgrade.
28