Reference Guide

Table Of Contents
Windows 10 gateway system<Windows installed
drive>\Users\<user_name>\AppData\Local\Temp\generated\logs
After the cluster update is over, DSU logs for individual nodes can be found in the <Windows
Directory>\Temp\OMIMSWAC folder on the respective nodes.
To run the compliance report again, click Re-run Compliance and repeat steps 4 to 7.
10. After the updates are downloaded, follow the instructions in the Windows Admin Center to install both operating system
and hardware updates. If the UI session is live, the node level progress status is displayed. Windows Admin Center creates a
notification once the update is completed.
Updating a stand-alone node before adding it to the cluster
Before creating a cluster, ensure that each node is updated with the latest versions of firmware and drivers.
Steps
1. In Windows Admin Center, in the left pane, click Add.
2. In the Windows Server tile, click Add.
3. Enter the node name and click Add.
4. Under All connections, select the server and click Manage as.
5. Select use another account for this connection, and then provide the credentials in the domain\username or
hostname\username format.
6. Click Confirm.
7. In the Connections window, click the server name.
8. In the left pane of Windows Admin Center, under EXTENSIONS, click OpenManage Integration.
9. Review the Dell EMC Software License Agreement and Customer Notice, and select the check box to accept the
terms of the license agreement.
10. Go to the Update tab and, select either the online catalog or offline catalog.
11. Click Next: Compliance Details, select all the updates, and click Next: Summary and then Next: Update.
Known issues
The following table lists known issues and workarounds related to OpenManage Integration with Microsoft Windows Admin
Center with Microsoft HCI Solutions from Dell Technologies clusters.
NOTE:
For details about troubleshooting steps and known issues, see the Dell EMC OpenManage Integration Version 2.0.0
with Microsoft Windows Admin Center Users Guide at https://www.dell.com/support/home/product-support/product/
openmanage-integration-microsoft-windows-admin-center/docs.
Table 1. Known issues
Issue Resolution/workaround
Running Test-Cluster fails with network communication
errors.
With USB NIC enabled in iDRAC, if you run the Test-
Cluster command to verify the cluster creation readiness or
cluster health, the validation report includes an error indicating
that the IPv4 addresses assigned to the host operating
system USB NIC cannot be used to communicate with the
other cluster networks.
This error can be safely ignored. To avoid the error,
temporarily disable the USB NIC (labeled as Ethernet, by
default) before running the Test-Cluster command.
The USB NIC network appears as a partitioned cluster
network.
When the USB NIC is enabled in iDRAC, cluster networks in
the failover cluster manager show the networks associated
with the USB NIC as partitioned. This issue occurs because
the cluster communication is enabled by default on all network
Remove the USB NIC from any cluster communication by
using the following script:
$rndisAdapter = Get-NetAdapter -
InterfaceDescription 'Remote NDIS
Compatible Device' -ErrorAction
SilentlyContinue
Day 0 Operations 25