User Guide

The 250-W power supply can operate from an AC power source of 115 VAC or 230 VAC at 50 60 Hz. The power supply
provides the DC operating voltages and currents listed in the following table.
Output Voltage
1
Minimum Current (A)
Maximum Current (A)
2
+12 VDC 0.0
16.0
3
+5 VDC
1.0/0.2
4
22.0
+3.3 VDC
0.1/0.0
5
18.0
- - -
–12 VDC 0.0 1.0
+5 VFP 0.0 2.0
1
Outputs will meet and not exceed SELV requirements per electrical standards, i.e. UL 60950, IEC 60950, EN60950
PAR.2.3.
2
Maximum continuous combined load on +5 VDC and +3.3 VDC outputs will not exceed 150 watts.
3
Peak +12 VDC output power (up to 17.0 amps) will not exceed 15 seconds in duration. Under this condition, tolerance on
the +12v output, is allowed to be +/- 10%.
4
+5 VDC minimum load will be 0.2A when there is a minimum load of 0.3A on the +12 VDC and 0.42A on the +3.3 VDC
outputs simultaneously. +5V min load is 1A for load transient tests.
5
In system applications where +3.3VDC is not used, all other outputs will stay within regulation while the +3.3 VDC output