Users Guide

2018 2 26 NetXtreme-E-UG100 ページ 41
システムレベル設定
NetXtreme-E ユーザー マニュアル
•[P1] - ポート 1 の設定
•[P2] - ポート 2 の設定
•[AN] - 自動ネゴシエーション
[No AN/ANなし] - 強制された速度
24:サポートされるリンク速度設定の組み合わせ
Port1 Link Speed
Setting
Port 2 Link Setting
Forced 1G Forced 10G Forced 25G AN Enabled {1G}
AN Enabled
{10G}
AN Enabled
{25G}
AN Enabled {1/
10G}
AN Enabled {1/
25G}
AN Enabled {10/
25G}
AN Enabled {1/10/
25G}
Forced 1G P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN
P2: no AN P2: no AN P2: no AN P2: {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {1/25G} P2: AN {10/25G} P2: AN {1/10/25G}
Forced 10G P1: no AN P1: no AN Not supported P1: no AN P1: no AN Not supported P1: no AN P1: no AN P1: no AN P1: no AN
P2: no AN P2: no AN P2: {1G} P2: {10G} P2: AN {1/10G} P2: AN {1G} P2: AN {10G} P2: AN {1/10G}
Forced 25G P1: no AN Not supported P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN
P2: no AN P2: no AN P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {1/25G} P2: AN {25G} P2: AN {1/25G}
AN Enabled
{1G}
P1: {1G} P1: {1G} P1: {1G} P1: AN {1G} P1: AN {1G} P1: AN {1G} P1: AN {1G} P1: AN {1G} P1: AN {1G} P1: AN {1G}
P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {1/25G} P2: AN {10/25G} P2: AN {1/10/25G}
AN Enabled
{10G}
P1: AN {10G} P1: AN {25G} Not supported P1: AN {10G} P1: AN {10G} Not supported P1: AN {25G} P1: AN {10G} P1: AN {10G} P1: AN {10G}
P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {1G} P2: AN {1G} P2: AN {10G} P2: AN {1/10G}
AN Enabled
{25G}
P1: AN {25G} Not supported P1: AN {25G} P1: AN {25G} Not supported P1: AN {25G} P1: AN {1/10G} P1: AN {25G} P1: AN {25G} P1: AN {25G}
P2: no AN P2: no AN P2: AN {1G} P2: AN {25G} P2: AN {1/10G} P2: AN {1/25G} P2: AN {25G} P2: AN {1/25G}
AN Enabled
{1/10G}
P1: AN {1/10G} P1: AN {1/10G} P1: AN {1G} P1: AN {1/10G} P1: AN {1/10G} P1: AN {1/10G} P1: AN {1/25G} P1: AN {1G} P1: AN {1/10G} P1: AN {1/10G}
P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {1G} P2: AN {10G} P2: AN {1/10G}
AN Enabled
{1/25G}
P1: AN {1/25G} P1: {1G} P1: AN {1/25G} P1: AN {1/25G} P1: AN {1G} P1: AN {1/25G} P1: AN {10/25G} P1: AN {1/25G} P1: AN {1/25G} P1: AN {1/25G}
P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {1/25G} P2: AN {25G} P2: AN {1/25G}
AN Enabled
{10/25G}
P1: AN {10/
25G}
P1: {10G} P1: AN {25G} P1: AN {10/25G} P1: AN {10G} P1: AN {25G} P1: AN {1/10/25G} P1: AN {25G} P1: AN {10/25G} P1: AN {10/25G}
P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {25G} P2: AN {10/25G} P2: AN {1/10/25G}
AN Enabled
{1/10/25G}
P1: AN {1/10/
25G}
P1: {1/10G} P1: AN {1/25G} P1: AN {1/10/
25G}
P1: AN {1/10G} P1: AN {1/25G} P1: AN {1/10/25G} P1: AN {1/25G} P1: AN {1/10/25G} P1: AN {1/10/25G}
P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {1/25G} P2: AN {10/25G} P2: AN {1/10/25G}
注:1Gbps のリンク速度を実現するには、サポートされている光トランシーバまたは直接接続の
銅線ケーブルを使用してください。