Administrator Guide

554 Fabric OS Administrator’s Guide
53-1002920-02
End-to-end performance monitoring
23
The Brocade 300, 5300, 5410, 5424, 5430, 5450, 5460, 5470, 5480, and 7800 models
allow up to 768 end-to-end monitors shared by all ports in the same ASIC. Also, these models
allow up to 192 end-to-end monitors per port.
The number of interswitch links (ISLs) configured on the switch affects the amount of resources
available for end-to-end monitors.
Virtual Fabrics considerations: If Virtual Fabrics is enabled, the Brocade DCX, DCX-4S, DCX 8510,
and 5300 models allow up to 256 end-to-end monitors on one logical switch. The Brocade 5100,
6510, 6520, and VA-40FC allow up to 341 end-to-end monitors on one logical switch.
Supported port configurations for EE monitors
You can configure EE monitors on F_Ports and, depending on the switch model, on E_Ports. The
following platforms support EE monitors on E_Ports:
Brocade 6505
Brocade 6510
Brocade 6520
Brocade M6505
Brocade 6547
Brocade DCX 8510 family
Identical EE monitors cannot be added to the same port. Two EE monitors are considered identical
if they have the same SID and DID values after applying the end-to-end mask.
An EE monitor and a port Top Talker monitor cannot coexist on the same port.
Coexistence of EE monitors and Top Talker monitors on ports belonging to the same ASIC is not
recommended because the statistics for the same flow going through ports on the same ASIC may
be inaccurate.
Adding EE monitors
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the following command:
perfaddeemonitor [slotnumber/]portnumber sourceID destID
When you add an EE monitor to a port, specify the sourceID and destID in the ingress direction. For
example, Figure 78 shows two devices:
Host A is connected to domain 1 (0x01), switch area ID 18 (0x12), AL_PA 0x00.
Dev B is a storage device connected to domain 2 (0x02), switch area ID 30 (0x1e), AL_PA
0x00.
FIGURE 78 Setting end-to-end monitors on a port
Domain 1
Host A Dev B
SID = 0x011200
DID = 0x021e00
Domain 2
Monitor 1 Monitor 2 Monitor 3 Monitor 4
F_PortF_Port E_Port E_Port
14
13
2
3