Administrator Guide

Fabric OS Administrator’s Guide 79
53-1002920-02
Switch activation and deactivation
2
Disabling a switch
You must disable a switch before making configuration changes or before running offline
diagnostic tests.
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the switchDisable command.
switch:admin> switchdisable
All Fibre Channel ports on the switch are taken offline. If the switch is part of a fabric, the fabric
is reconfigured.
If Virtual Fabrics is enabled, only the ports allocated to the logical switch are disabled. To
disable all of the ports, you must disable the entire chassis. See “Disabling a chassis” on
page 79.
Enabling a switch
The switch is enabled by default after it is powered on and switch initialization routines have
finished. You must re-enable the switch after making configuration changes or running offline
diagnostics.
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the switchEnable command.
switch:admin> switchenable
All Fibre Channel ports that passed Power On Self Test (POST) are enabled. If the switch has
inter-switch links (ISLs) to a fabric, it joins the fabric.
If Virtual Fabrics is enabled, only the ports allocated to the logical switch are enabled. To
enable all of the ports, you must enable the entire chassis. See “Enabling a chassis”.
Disabling a chassis
Disabling a chassis disables all Fibre Channel ports on all logical switches in the chassis. You must
disable a chassis before making chassis-wide configuration changes or before running offline
diagnostic tests.
1. Connect to any logical switch in the chassis and log in using an account assigned to the admin
role.
2. Enter the chassisDisable command.
TABLE 5 Ports affected when you enable or disable a switch in VF or non-VF mode
Operation Virtual Fabrics enabled Virtual Fabrics not enabled
Enable switch Enables all ports on logical switch Enables all ports on physical chassis
Enable chassis Enables all ports on physical chassis Not allowed
Disable switch Disables all ports on logical switch Disables all ports on physical chassis