Messages Reference Guide

140 Fabric OS Message Reference
53-1002749-01
ANV-1001
5
ANV Messages
ANV-1001
Message Port <port number> port fault. Change the SFP or check the cable.
Message Type LOG
Severity ERROR
Probable Cause Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.
Recommended
Action
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable, if
necessary.
ANV-1002
Message Port <port number> chip faulted due to an internal error.
Message Type LOG | FFDC
Severity ERROR
Probable Cause Indicates an internal error. All the ports on the chip will be disrupted.
Recommended
Action
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastBoot command on the switch.
ANV-1003
Message S<slot number>,C<chip index>: HW ASIC Chip error. Type = 0x<chip error type>,
Error = <chip error string>.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the blade.