Messages Reference Guide

552 Fabric OS Message Reference
53-1002749-01
HIL-1206
5
HIL-1206
Message Fan <fan number> sensor <sensor number> , speed (<measured speed> RPM) below
threshold.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the specified fan speed (in RPM) has fallen below the minimum threshold. This problem
can quickly cause the switch to overheat. This message is specific to non-bladed switches.
Recommended
Action
Replace the fan field-replaceable unit (FRU).
HIL-1207
Message Fan <fan number> is faulty.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the fan is faulty.
Recommended
Action
Use the tempShow command to verify that the switch temperatures are within operational ranges. Refer
to the hardware reference manual for the temperature range of your switch.
Make sure that the area is well-ventilated and that the room temperature is within the operational range
of your switch. Refer to the hardware reference manual for your switch for the operational temperature
range.
Use the fanShow command to monitor the status of the fan generating this error.
If the fan continues to generate this message, replace the switch because the fan is not field-replaceable.
HIL-1208
Message Fan <fan number> is not faulty.
Message Type LOG
Severity INFO
Probable Cause Indicates that the fan is not faulty.
Recommended
Action
This can only occur on switches with non-removable fans. It follows a previous indication of faultiness.
If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.