Deployment Guide

SFP class default settings (Continued)TABLE 8
Area Description Default threshold settings Default alarm
settings
Threshold state
Receive power
(RXP)
Monitors receive
power
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Below: 1
Above: 1
Out_of_range
Out_of_range
Transmit power
(TXP)
Monitors transmit
power
Unit: µW
Time Base: none
Low: 0
High: 5000
Buffer: 25
Below: 1
Above: 1
Out_of_range
Out_of_range
Current Monitors SFP current Unit: mAmps
Time Base: none
Low: 0
High: 50
Buffer: 1
Below: 1
Above: 1
Out_of_range
Out_of_range
Voltage Monitors SFP electrical
force
Unit: mVolts
Time Base: none
Low: 2970
High: 3630
Buffer: 10
Below: 1
Above: 1
Out_of_range
Out_of_range
Power on hours Monitors the number of
hours the SFP is
powered on.
Unit: Changes
Time Base: none
Low: 0
High: 0
Buffer: 0
Below: 0
Above: 0
Informative
Informative
Performance monitoring guidelines and default settings
Performance monitoring serves as a tuning tool. The Performance Monitor class groups areas that
track the source and destination of traffic. Use the Performance Monitor class thresholds and alarms
to determine traffic load and flow and to reallocate resources appropriately.
NOTE
Performance Monitoring is not supported on VE_Ports.
Performance monitoring guidelines and default settings
54 Fabric Watch Administrators Guide
53-1003142-01