Brocade Fabric OS v7.2.0a Release Notes v1.0 September 9, 2013 Document History Document Title Summary of Changes Publication Date Brocade Fabric OS v7.2.0a Release Notes v1.0 Initial Release September 9, 2013 Fabric OS v7.2.0a Release Notes v1.
© 2013 Brocade Communications Systems, Inc. All Rights Reserved. ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, and Vyatta are registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their respective owners.
Contents Overview ...................................................................................................................................................... 5 New Hardware Support ........................................................................................................................................... 5 Summary of New Software Features ......................................................................................................................
FCR and Integrated Routing .................................................................................................................................. 33 Forward Error Correction (FEC) ............................................................................................................................. 33 FICON......................................................................................................................................................................
Overview Fabric OS (FOS) v7.2.0a is a patch release based on FOS v7.2.0. All hardware platforms and features supported in FOS v7.2.0 are also supported in FOS v7.2.0a. New Hardware Support FOS v7.2 does not introduce support for any new hardware platform, while it adds support for the existing embedded switches 5431, 6547 and M6505 on a major FOS release. Summary of New Software Features FOS v7.
New Feature Descriptions MAPS (Monitoring and Alerting Policy Suite) FOS v7.2 implements a new easy to use policy based monitoring and alerting suite that proactively monitors the health and performance of the SAN infrastructure to ensure application uptime and availability. Brocade MAPS helps users to uncover potential problems in the SAN fabric quickly, before they cause application performance impacts or costly failures.
minute, send an e-mail notification when the error rate is at five per minute, and fence a port when the error rate exceeds ten per minute. Ability to monitor both sudden failures and gradual degradations MAPS provides the ability to not only detect abnormal conditions but also gradually deteriorating conditions in the switch. For example, if a CRC error counter at a switch port increments suddenly at the rate of five per minute, MAPS can detect and alert the end users about that condition.
Bottleneck Detection integration with MAPS dashboard Bottleneck Detection information is integrated with MAPS dashboard. The “Summary” section of the dashboard shows bottleneck events detected by the Bottleneck Monitor. The “History” section of the dashboard shows entries for bottlenecked ports, including transient bottlenecks that are not detected by the Bottleneck Monitor. This enables users to get at an instant view of the bottlenecked ports in the switch and enables rapid problem resolution.
Flow Generator: Flow generator is a test traffic generator for pre-testing the SAN infrastructure (including internal connections) for robustness before deploying the applications. Allows users to configure a16G FC capable port as a simulated device that can transmit frames at full 16G line rate.
ClearLink Diagnostics: D_Port Enhancements FOS v7.2 adds the following D_Port enhancements: Enhancement to D_Port test results Starting with FOS v7.2 complete results of the D_Port tests will be available on the responder switch as well. Prior to FOS v7.2, D_Port test results on the D_Port responder switch did not include optical and remote loopback test results. Complete results were only available on the D_Port initiator switch. D_Port support between Brocade 16G HBA and Brocade 16G Access Gateway.
FOS v7.2 allows buffer credit assignment even for “normal distance” (regular) E_ports The portCfgEportCredits CLI introduced in FOS v7.2 allows users to perform fine grained performance tuning on normal E_ports by allowing users to specify buffer credits. In FOS v7.2, the portaddess CLI has been enhanced to display an address as user bound when a user has explicitly bound an address to a port. FOS v7.
Optionally Licensed Software Fabric OS v7.2 includes all basic switch and fabric support software, as well as optionally licensed software that is enabled via license keys. Optionally licensed features include: Brocade Ports on Demand—Allows customers to instantly scale the fabric by provisioning additional ports via license key upgrade. (Applies to select models of switches).
Adaptive Networking with QoS—Adaptive Networking provides a rich framework of capability allowing a user to ensure high priority connections obtain the bandwidth necessary for optimum performance, even in congested environments. The QoS SID/DID Prioritization and Ingress Rate Limiting features are the first components of this license option, and are fully available on all 8Gb and 16Gb platforms. Note : With FOS v7.
10GbE FCIP/10G Fibre Channel – This license enables the two 10GbE ports on the FX8-24 and/or the 10G FC capability on FC16-xx blade ports supported on DCX 8510 platforms. On the Brocade 6510, Brocade 6520 this license enables 10G FC ports.
Temporary License Support The following licenses are available in FOS v7.
Supported Switches FOS v7.2 supports the following existing platforms: 300, 5100, 5300, 7800, VA-40FC, Brocade Encryption Switch, DCX, DCX-4S 6505, 6510, 6520, DCX 8510-8, DCX 8510-4 FC16-32, FC16-48, FC8-32E, FC8-48E, FX8-24, FS8-18 on DCX 8510-8/DCX 8510-4 FC8-16, FC8-32, FC8-48, FC8-64, FX8-24, FS8-18, FCOE10-24 on DCX/DCX-4S 5410, 5424, 5430, 5450, 5480, 5470, 5460, NC-5480 Support merged to FOS v7.2: 5431, 6547, M6505 Access Gateway mode is also supported by Fabric OS v7.
Switch operating system version Error numbers and messages received supportSave command output and associated files o For dual CP platforms running FOS v6.
FOS Migration Considerations This section contains important details to consider before migrating to or from this FOS release. FOS Upgrade and Downgrade Special Considerations DCX/DCX-4S units running any FOS v7.1 can be non-disruptively upgraded to FOS v7.2.0a. This upgrade is nondisruptive to both FC and FCoE traffic (when using FCOE10-24 blades). Any firmware activation on Brocade 7800, or DCX, DCX-4S, DCX 8510-8, DCX 8510-4 with FX8-24 will disrupt I/O traffic on the FCIP links.
Important Notes This section contains information that you should consider before you use this Fabric OS release. Brocade Network Advisor Compatibility Brocade Network Advisor greatly simplifies the steps involved in daily operations while improving the performance and reliability of the overall SAN and IP networking environment. Brocade Network Advisor unifies, under a single platform, network management for SAN, LAN and converged networks.
SMI Compatibility It is important to note that host SMI-S agents cannot be used to manage switches running FOS v7.2. If users want to manage a switch running FOS v7.2 using SMI-S interface, they must use Brocade Network Advisor’s integrated SMI agent. Fabric OS Compatibility The following table lists the earliest versions of Brocade software supported in this release, that is, the earliest supported software versions that interoperate.
Multi-Protocol Router Interoperability Brocade 7500 and FR4-18i blade V6.2.2 and higher 4 6 8 McDATA SANRouters 1620 and 2640 Not Supported NOS (VDX Platform) Interoperability Brocade VDX6710, VDX6720, VDX6730 NOS v2.1.1 or later7 Brocade VDX8770 NOS 3.0 or later Table Notes: 1 When routing to an M-EOS edge fabric using frame redirection, the M-EOS fabric must have a FOS-based product in order to configure the frame redirection zone information in the edge fabric.
the zoning database is greater than 128KB. In such scenarios zoning operations such as cfgsave/cfgenable can still be performed successfully if initiated from a switch running FOS v7.0 or later. SNMP Support Starting with FOS v7.2, the Fabric OS MIB Reference document is not updated. You can obtain the latest MIBs from the downloads area of MyBrocade site after logging in. For information about SNMP support in Fabric Operating System (FOS) and how to use MIBs, see the Fabric OS Administrator’s Guide.
Deprecated/Obsoleted MIBs swFCPortSpeed in SW.mib is obsoleted. Customized OID is not supported from 7.1.0 release. Blade Support Fabric OS v7.2 software is fully qualified and supports the blades for the DCX/DCX-4S noted in the following table: DCX/DCX-4S Blade Support Matrix 16-, 32-, 48- and 64-port 8Gbit port blades (FC8-16, FC8-32, FC8-48, FC8-64) Supported with FOS v6.0 and above (FC8-64 requires FOS v6.4) with any mix and up to 8/4 of each. No restrictions around intermix.
Fabric OS v7.2 software is fully qualified and supports the blades for the DCX 8510-8 and DCX 8510-4 noted in the table below. DCX 8510-8/DCX 8510-4 Blade Support Matrix FC16-32, FC16-48 16G FC blades FOS v7.0 or later. FC8-64 64 port 8Gbit port blade With any mix and up to 8/4 of each. No restrictions around intermix. Note: FC8-16, FC8-32, FC8-48 blades are not supported on DCX 8510 platforms. FC8-32E, FC8-48E FOS v7.0.1 or later. Intelligent blade Up to a total of 8/4 intelligent blades.
Power Supply Requirements for Blades in DCX/DCX-4S Blades Type of Blade FC10-61, FC816, FC8-32, FC 8-48, FC864 Port Blade FR4-18i1 FS8-18, FX8-24, FCOE10-24 DCX/DCX-4S DCX/DCX-4S @110 VAC (Redundant configurations) @200-240 VAC (Redundant configurations) 2 Power Supplies 2 Power Supplies Intelligent Blade Not Supported 2 Power Supplies Intelligent Blade Not Supported DCX: 2 or 4 Power Supplies Comments DCX-4S: 2 Power Supplies Distribute the Power Supplies evenly to 2 different AC con
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Type of Blade DCX 8510-8 @110 VAC (Redundant configurations) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments Any combination of 8Gb or 16Gb ports with QSFP ICLs FC8-64, FC16-32, FC8-32E Port Blade 4 Power Supplie
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Type of Blade DCX 8510-8 @110 VAC (Redundant configurations) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments 384 16Gb ports + QSFP ICLs FC16-32, FC16-48 Port Blade Not Supported 4 Power Supplies 200-240VAC: For
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-4 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-4 Backbone Hardware Reference Manual) Configured Blades Number of Ports Type of Blade DCX 8510-4 @110 VAC (Redundant configurations) DCX 8510-4 @200-240 VAC (Redundant configurations) Comments 96 ports max with QSFP ICLs FC16-32, FC8-32E Port Blade 2 Power Supplies 2 Power Supplies 1+1 redunda
If FOS v7.2 or later is factory installed (or net installed), Adaptive Networking features are always available. This matches the behavior of the Brocade 6520 and all products shipping with prior versions of FOS and with the Adaptive Networking license factory installed. Ports will come up in AE mode by default If the remote port supports QOS and is not explicitly disabled, the link will come up in QOS mode. Otherwise, the link will come up in normal mode.
Gen 5 platforms and blades are capable of setting an EHT value on an individual port basis. On 8G platforms EHT is set on an ASIC-wide basis, meaning all ports on a common ASIC will have the same EHT setting. Extra care should be given when configuring EHT on 8G platforms or Gen 5 platforms with 8G blades to ensure E_Ports are configured with an appropriate Hold Time setting. When using Virtual Fabrics and creating a new Logical Switch when running FOS v7.1.
With Windows and Veritas Volume Manager/Veritas Dynamic Multipathing, when LUN sizes less than 400MB are presented to BES for encryption, a host panic may occur and this configuration is not supported in the FOS v6.3.1 or later release. Hot Code Load from FOS v7.1.x to FOS v7.2 or later is supported. Cryptographic operations and I/O will be disrupted but other layer 2 FC traffic will not be disrupted.
FCoE/DCB/CEE (FCOE10-24) When upgrading a DCX/DCX-4S with one or more FCOE10-24 blades from FOS v6.x to FOS v7.0.0 or later, the user should carefully review Chapter 5 of the FOS v7.0.0 Converged Enhanced Ethernet Administrator’s Guide. Ethernet L2 traffic with xSTP Hello timer set to less than or equal to 3 seconds may experience momentary traffic disruption during HA failover. Hot plugging a CP with firmware level less than FOS v6.3.
are identical this merge logic guarantees uniqueness in any modified login group name (switches with the same OUI will have unique last 3 bytes in WWN). However, if the participating switches have different OUIs but identical last three bytes in the switch WWNs, then the merge logic will fail to guarantee uniqueness of login group names. This will result in one of the login groups being dropped from the configuration.
FL_Port (Loop) Support FL_Port is not supported on FC16-32, FC16-48, FC8-32E, FC8-48E, Brocade 6510, Brocade 6505 and Brocade 6520. The FC8-48 and FC8-64 blade support attachment of loop devices. Virtual Fabrics must be enabled on the chassis and loop devices may only be attached to ports on a 48-port or 64-port blade assigned to a non-Default Logical Switch operating with the default 10bit addressing mode (they may not be in the default Logical Switch).
speeds when compared to 8G/4G/2G speeds. Because of this, Fabric Watch alerts and Port Fencing based on ITW (Invalid Transmission Word) thresholds will not function as these enc_in and enc_out counters will not be incremented when operating at either 10G or 16G (ITW is computed based on enc_in and enc_out counters). Also any CLI or GUI that displays enc_in and enc_out counters will show no incrementing of these counters when a port is operating at either 10G or 16G.
When using anonymous ftp, to avoid long delays or failure of simultaneous supportsave collections when AP blades are present in a director chassis, the number of unlimited anonymous users for a Windows FTP server should be configured as follows: Number of anonymous FTP connections = (Number of director chassis) + (Number of installed Application Blades x 3) RASlog message AN-1010 may be seen occasionally indicating “Severe latency bottleneck detected”.
Defects Open Defects in Fabric OS v7.2.0a This section lists defects with High or Medium Technical Severity open in Fabric OS v7.2.0a as of 12:00 PM on September 9, 2013. While these defects are still formally open they are unlikely to impede Brocade customers in their deployment of Fabric OS v7.2.0a and have been deferred to a later release. None of these defects have the requisite combination of probability and severity to cause significant concern to Brocade customers.
Open Defects in Fabric OS v7.2.0a Defect ID: DEFECT000473063 Technical Severity: High Summary: Changing a FID/LS to base fabric should check for the presence of SIM ports, otherwise they get stuck as G-ports, etc. Symptom: Ports that are configured as SIM ports in a FID get stuck in an invalid state, if the switch is reconfigured to become the Base FID (an invalid state for SIM ports). Workaround: Easily reproducible. No possible workaround known at this time.
Open Defects in Fabric OS v7.2.0 This section lists defects with High or Medium Technical Severity open in Fabric OS v7.2.0 as of 12:00 PM on July 26, 2013.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000423640 Technical Severity: High Summary: Upgrade a flash card driver version. Symptom: On rare occasions excessive writing to an old flash card could cause it no longer be accessible during switch bootup. Feature: Embedded Platform Services Function: Other Service Request ID: ,1162762 Reported In Release: FOS6.4.3_dcb Probability: Low Defect ID: DEFECT000425974 Technical Severity: High Summary: Fabric Watch reports all zeros for 16G SFPs.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000432406 Technical Severity: High Summary: Hung supportsave processes left on switch and eventually triggered switch panic. Symptom: Customer observes multiple supportsave processes on switch without actively initiating a recent supportsave. These processes can cause memory to be held when an additional supportsave is initiated and lead to switch panic.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000450265 Technical Severity: High Summary: Multiple NSD ASSERTS after duplicate wwn detection, cold recovery resulted. Symptom: CP failover occurs after nsd process terminates due to duplicate wwn in fabric. Feature: FOS Software Function: Panic / OOM Service Request ID: 1152307 Reported In Release: FOS6.4.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000459843 Technical Severity: High Summary: All supportsaves have module timeouts and take more than 55 minutes to complete in Port Throttling case. Symptom: All supportsaves have module timeouts and take more than 55 minutes to complete in Port Throttling case. Workaround: Workaround is to use the CLI supportsave -t 2 option. Feature: 16G Platform Services Function: FOS Kernel Drivers Reported In Release: FOS7.2.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000467681 Technical Severity: High Summary: Blade server shows incorrect firmware version in IOM module after a switch hotplug Symptom: Blade server displays incorrect Firmware Version in IOM module after switch hotplug Feature: Embedded Platform Services Function: Other Service Request ID: 1001 Reported In Release: FOS7.2.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000468556 Technical Severity: High Summary: iswitchd failures on 6510 acting as FCR Backbone Symptom: Switch console may display iswitchd failures during hafailover on core director. No impact to IO. Feature: 8G FCR Function: FCR Daemon Reported In Release: FOS7.2.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000349576 Technical Severity: Medium Summary: Unexpected error message is given by Web Tools 1) while removing the uncommitted static F port mapping, in the presence of WWN – N port mapping 2) While removing the uncommitted WWN-N port mapping, in the presence of static F port mapping. Symptom: Display of this wrong confirmation message by Web Tools may mislead the user.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000420903 Technical Severity: Medium Summary: Graphic for external management port is lit with no connection for 6547 switch. Symptom: when RJ45 cable is removed from the switch faceplate, Webtools still shows external management port with solid green LED. Feature: Mgmt Embedded - CAL Function: Other Reported In Release: FOS7.0.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000433534 Technical Severity: Medium Summary: [H1520]FW-1403 event after Flash value crosses low threshold from below to inbetween. Symptom: FW-1403 generated when Flash value crosses its low threshold from below to inbetween during low threshold testing and high threshold is tested previously Feature: FABRIC WATCH Function: Other Service Request ID: 1118425,743111 Reported In Release: FOS7.0.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000450457 Technical Severity: Medium Summary: ipfilter does not block access to port 80 Symptom: When using ipfilter to block port 80, port 80 is still accessible. When connecting to the switch, "Interface disabled" and "This Interface (x.x.x.x) has been disabled by the adminstrator." is presented to the user.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000455170 Technical Severity: Medium Summary: When user issued 'date' command, switch will output the 'No license installed' message on CLI. Symptom: On a switch without license installed, run "date" command will disaplay: No licenses installed. External Time Synchronization in place in Switch. Cannot execute this command. Feature: FOS Software Function: OS: Linux Service Request ID: 1167588 Reported In Release: FOS7.1.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000461016 Technical Severity: Medium Summary: When moving Xge ports between Logical Switches the Xge ports will not enable after a portenable in the new Logical Switch. Symptom: After moving an enabled XGE port from LS to a different LS, the XGE port remains disabled after port enable in the new switch.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000465422 Technical Severity: Medium Summary: D-Port Testing Fails and the reasons for failure is not received as part of CAL in automatic mode Symptom: D-Port Testing fails when setting the Link Traffic Test Params for F to HBA links without any reason in automatic mode. Feature: Mgmt Embedded - CAL Function: Other Reported In Release: FOS7.2.
Open Defects in Fabric OS v7.2.0 Defect ID: DEFECT000466750 Technical Severity: Medium Summary: In Switch Events and Switch information tab, the last updated time shows the Host time instead of showing the Switch time. Symptom: Misleading last updated time in Switch Events and Switch Information tab. Feature: WebMgmt Function: Switch Explorer/Switch View Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.0a This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of September 9, 2013 in Fabric OS v7.2.0a Defect ID: DEFECT000433200 Technical Severity: Medium Summary: Switch cannot be managed from WebTools or BNA though management via CLI works. Symptom: Under rare condition management process (HTTPD) gets stuck and switch reports as unreachable via BNA and Webtools.
Closed defects with code change in Fabric OS v7.2.0a Defect ID: DEFECT000465730 Technical Severity: Medium Summary: Enhancement to asic parity error monitoring threshold Symptom: Current default configuration for blade faults is not sensitive enough for some ficon environment setup. Customer may experience IFCCs when there are low level asic parity errors. New CLI options will allow blade to be faulted sooner when there are parity errors. Default threshold is maintained the same as Pre-FOS7.
Closed defects with code change in Fabric OS v7.2.0a Defect ID: DEFECT000468007 Technical Severity: High Summary: Host discovery issues via Ex ports on ICL in multi chassis configuration Symptom: Host may not see all target LUNs in a topology using multi-chassis EX ports on ICL configuration Workaround: Portdisable enable switch ports for affected devices. Probability: Medium Feature: FC Services Function: Name Server Reported In Release: FOS7.2.
Closed defects with code change in Fabric OS v7.2.0a Defect ID: DEFECT000470123 Technical Severity: High Summary: Switch running agshow panics or BNA seed switch panics when polling for AG info in a fabric with AG switches. Symptom: After the port connecting AG to switch bounces, before fabric management server and name server data base are stabilized, polling from BNA caused seed switch to panic, similarly run agshow on switch can cause switch to panic.
Closed with Code Change in Fabric OS v7.2.0 This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of July 26, 2013 in Fabric OS v7.2.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000404322 Technical Severity: Medium Summary: Diagnostics do not attain saturation of 3.2G throughput over long distance E-port due to reduced size frames Symptom: Expected throughput of 3.2G for Long Distance E-Port is not obtained during spinfab test using 16G LWL 10km SFP Risk of Fix: Low Feature: Diagnostics Function: Other Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000418249 Technical Severity: High Summary: spinfab is failing ports when the option -nframes 0 is run on multiple switches at the same time in a fabric. Symptom: Failed messages and ports seen after running spinfab -nframes 0. Workaround: spinfab -nframes 0 can be run in serial on mupltiple switches instead of in parallel. Risk of Fix: Low Probability: Medium Feature: Diagnostics Function: Other Reported In Release: FOS7.1.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000422596 Technical Severity: Medium Summary: sw.mib syntax error. Symptom: sw.mib fails to load in management application Workaround: Manually edit the SW.mib file Risk of Fix: Low Probability: Low FOS Software Feature: Function: SNMP Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000427535 Technical Severity: Medium Summary: After setting a low threshold for SFP temperature on BR6505, The temperature is shown as above instead of Below. Symptom: After a custom setting for SFP temperature of HIGH =85 and Low - 75, even if the temperature is below 75, it is shown as above and not below. Risk of Fix: Low Feature: FOS Software Function: EM / Hil / Sysctrl Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000428794 Technical Severity: Medium Summary: If portloopbacktest with -nframes are performed on portblade of DCX8510, the port LED behavior behaves differently if -nframes option is not specified Symptom: If portloopbacktest with -nframes are performed on portblade of DCX8510, the port LED behavior is repeating the following sequence with having top and bottom 16 ports behaving differently.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000429712 Technical Severity: Medium Summary: BR5100 does not transmit SNMP trap as chassis instance after user configured sysmonitor. Symptom: SNMP trap and errdump indicates error with FID:128 even though sysmonitor is a chassis-wide command. Risk of Fix: Low Probability: Medium Feature: Mgmt Embedded - SNMP Function: Other Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000431095 Technical Severity: High Summary: diagshow command in interactive mode hangs and leads to high CPU utilization when telnet session is killed Symptom: High CPU utilization when telnet session with diagshow command in interactive mode is killed Risk of Fix: Low Probability: Low Feature: FOS Software Function: Diagnostics Reported In Release: FOS6.4.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000431920 Technical Severity: High Summary: Support the documented BRCD-FCIP-Ext MIB in MIB reference. Symptom: User will always see 0 for the below measures fcipExtendedLinkTcpDroppedPackets fcipExtendedLinkTcpSmoothedRTT fcipExtendedLinkRtxRtxTO fcipExtendedLinkRtxDupAck fcipExtendedLinkDupAck Risk of Fix: Low Probability: High Feature: Port Statistics Function: Other Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000432816 Technical Severity: Medium Summary: Logical port pid is manipulation when domain ID changes. Symptom: Port identifier of LISL port was not assigned correctly after setting LISL. Risk of Fix: Medium Probability: High Feature: FOS Software Function: Virtual Fabric FOS6.3.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000433865 Technical Severity: High Summary: 7800 panics when host writes data to tape drive via FCIP tunnel with fastwrite and tape pipelining enabled Symptom: Write I/Os failed after a few write I/Os were completed, 7800 panics. Workaround: Disable FCIP Fastwrite and tape pipelining Risk of Fix: Low Probability: Medium Feature: FOS Software Function: FCIP Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000435414 Technical Severity: Medium Summary: Error log content is getting cleared of prior messages when migrating to FOS 7.1.0 Symptom: After successful firmwaredownload upgrade to FOS 7.1.0, errdump results will not include any messages that were in the error log prior to the firmwaredownload. Only the latest messages appear.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000437078 Technical Severity: High Summary: Incompatible FDMI attribute between different FOS releases caused kernel panic Symptom: In a mixed FOS fabric with FOS v6.4.x and FOS v7.1, switch running v7.1.0 could panic when there are FDMI queries. Workaround: Do not use pre-v7.0 switches as BNA seed switch. Risk of Fix: Low Probability: Low Feature: FC Services Function: FDMI Reported In Release: FOS7.1.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000437958 Technical Severity: Medium Summary: Remove excessive internal I2C reset raslog message Symptom: i2c reset message on recoverable errors causing unnecessary concerns Risk of Fix: Low Probability: Low Feature: 8G Platform Services Function: Other FOS7.0.1 Reported In Release: Defect ID: DEFECT000438017 Technical Severity: Medium Summary: SNMP configuration replication overwrites AAA LDAP Settings.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000439725 Technical Severity: High Summary: The command IpAddrSet --delete is unsuccessful at removing an IPv6 switch address Symptom: Switch operations were not affected as the IPv6 address was not being used however, the IPv6 address could not be removed. Risk of Fix: Low Probability: Low Feature: OS Services Function: IP Admin Reported In Release: FOS7.1.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000440839 Technical Severity: High Summary: Incorrect route removed when switching TIzone from failover-enabled to failover-disabled Symptom: Changing a TIzone from failover enabled to disabled will cause traffic to stop and loss of access to the targets. Risk of Fix: Low Probability: Medium Feature: FC Services Function: Name Server Reported In Release: FOS7.1.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000441818 Technical Severity: Medium Summary: For 16GB fixed port count switches and port blades, the number of ports displayed by portledtest are not matching the number of physical front end facing FC ports Symptom: The overall functionality of portledtest is not affected however, portledtest displays results for internal as well as front facing ports.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000442467 Technical Severity: High Summary: Network Advisor initiated supportsave times out when collecting data Symptom: Observed the following from the Network Advisor masterlog. "One or more modules timed out during supportsave. retry supportsave with -t option to collect all logs." Risk of Fix: Low Probability: Medium Feature: Mgmt Embedded - CAL Function: Other Reported In Release: FOS7.1.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000444171 Technical Severity: High Summary: Data buffer is too small for holding frames header in error condition Symptom: Kernel panic on BR8000 switch with FCOE when sending several iterations of maximum number of FDISCs continually. Risk of Fix: Low Probability: Low Feature: CEE-FCOE Function: FCOE DRIVER Reported In Release: FOS6.4.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000445814 Technical Severity: Medium Summary: Configuration download failure when downloading fabric watch settings Symptom: After configuration download from CLI or using BNA to do partial fabric watch data replication, Bottleneck configurations were removed from the switch. Risk of Fix: Low Probability: Medium Feature: FOS Software Function: Management Services Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000447611 Technical Severity: High Summary: Disable auto tuning for 8G blades in 16G chassis. Only manual tuning will be supported for this combination. Symptom: After enabling auto tuning, FC8-64 blades faulted in a 16G chassis and the blade had to be power cycled to be recovered. Workaround: Disable auto tuning Risk of Fix: Medium Probability: Medium Feature: FOS Software Function: ASIC Driver Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000448752 Technical Severity: Medium Summary: Web Tools does not show Standby CP firmware level Symptom: Web Tools "Switch Admin | Fware Download panel" shows "none" for Standby CP level Risk of Fix: Low Probability: High Feature: WebMgmt Function: Firmware Download FOS7.1.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000451485 Technical Severity: Medium Summary: TU area threshold of portthconfig accepts invalid values outside the range 0-100 Symptom: TU area of e-port/fop-port accepts 999999999 for a value that is expressed as a percentage (0-100%) Risk of Fix: Low Feature: Performance Monitor Function: Frame Monitor FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000452033 Technical Severity: Medium Summary: CRC with good EOF on backend ports Symptom: CRC with good EOF on backend ports of FC8-64 blade in a DCX-8510. The following ports were observed to see CRCs with good EOF: 1/114, 10/154, and 11/154 Risk of Fix: Low Probability: High Feature: FOS Software Function: ASIC Driver Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000453432 Technical Severity: Medium Summary: Encryption Admin guide for DPM: Need to advertise that Keys should not be (Deactivated/Compromised/Destroyed) in the RKM KV without following decommission procedure Symptom: Following information will be seen in the Raslog for updating the DEKSon BES.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000454274 Technical Severity: Medium Summary: DCX-4S fails to send ACK1 to initial FLOGI from device that issues FLOGI immediately after link comes up Symptom: Occasionally observe that DCX4S fails to send ACK1 to FLOGI. Initial FLOGI times out, FLOGI resent from host and successfully receives ACK1. Risk of Fix: Medium Feature: FOS Software Function: Fabric Services Reported In Release: FOS7.1.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000455717 Technical Severity: High Summary: Request for message to be generated when the TKLM key vault comes back online successfully Symptom: Upon recovering the TKLM key vault and its successful re-connection, no message is generated indicating the event (cryptocfg --show -groupcfg verified that it was connected).
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000460296 Technical Severity: Medium Summary: Unit check during tape repositioning resulted in FICN-1056 FICON Emulation Error code 100 Symptom: Unit check during tape repositioning resulted in FICN-1056 FICON Emulation Error code 100 and ficon abort Workaround: Disable FICON Tape Read Pipelining on the FCIP Tunnel Risk of Fix: Low Feature: FOS Software Function: FCIP Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000462840 Technical Severity: High Summary: GPN_ID name server query for zoned and online device is rejected with reason: no portid Symptom: In Ficon setup, hosts may fail to establish paths due to name server query failures. Workaround: Set up ficon PDCM matrix to allow a port talk to itself. Risk of Fix: Low Probability: Low FOS Software Feature: Function: Fabric Services Reported In Release: FOS7.0.
Closed defects with code change in Fabric OS v7.2.0 Defect ID: DEFECT000464853 Technical Severity: Medium Summary: lfcfg --showall -xisl does not display header information for port 0 output Symptom: lfcfg --showall -xisl does not display "XISL Port No. : 0" in output. The "XISL Port No. :" is displayed for all other ports. Risk of Fix: Low Feature: FOS Software Function: Virtual Fabric Reported In Release: FOS7.1.
Closed without Code Change in Fabric OS v7.2.0 This section lists the defects with Critical, High and Medium Technical Severity closed without a code change as of July 26, 2013 in Fabric OS v7.2.0 Defect ID: DEFECT000412890 Technical Severity: Critical Summary: Upgrade to FOS 7.0.1b may cause certain storage ports to quit passing data Symptom: Loss of access to storage array while performing a FOS upgrade to 7.0.1b. Workaround: Port persistent disable/enable on the problem port to recover.
Closed defects without code change in Fabric OS v7.2.
Closed defects without code change in Fabric OS v7.2.0 Defect ID: DEFECT000462978 Technical Severity: High Summary: FS8-18 failure on an 8510 chassis Symptom: FS8-18 may fault with reason code 21 while coming up. Workaround: Reseat or powercycle the FS8-18 blade. Reason Code: Can Not Fix Probability: Medium Data Security Feature: Function: Platform Reported In Release: FOS7.1.
Closed defects without code change in Fabric OS v7.2.0 Defect ID: DEFECT000424424 Technical Severity: Medium Summary: Two devices over Routed VE/VEX fabric cannot estabish logical paths Symptom: Observed that the translate domain over VE/VEX ports is not in fabricshow and some hosts cannot communicates to targets. Reason Code: Not Reproducible Probability: Low Feature: FOS Software Function: Fabric Services Reported In Release: FOS7.0.
Closed defects without code change in Fabric OS v7.2.0 Defect ID: DEFECT000439119 Technical Severity: Medium Summary: Misleading (DPort + DWDM) instructions to "enable the port" to remove DWDM upon proper firmwaredownload failure. Symptom: Firmwaredownload is properly blocked but the instructions of "Portcfgdport --disable" command does not rectify the situation. Reason Code: Already Fixed in Release Probability: Medium Feature: FIRMWARE DOWNLOAD Function: FirmwareInstall Reported In Release: FOS7.0.
Closed defects without code change in Fabric OS v7.2.0 Defect ID: DEFECT000448985 Technical Severity: Medium Summary: Removing AN license key does not remove QoS functionality until link is dropped, need message added to AN license remove and AN license add functionality Symptom: If customer removes (or adds) the Adaptive Networking License Key, QoS functionality will not be active until the link is dropped; there is no message indicating this functionality.