Release Notes

Fabric OS v7.0.2 Release Notes v1.0 Page 17 of 99
Supported Products and FOS Interoperability
Supported Products and FOS InteroperabilitySupported Products and FOS Interoperability
Supported Products and FOS Interoperability
Secure Fabric OS (on any model) Not Supported
Mi10k, M6140, ED-6064, ES-3232, ES-4300, ES-4400, ES-4500, ES-
4700 (McDATA Fabric Mode and Open Fabric Mode)
1
Direct E_Port connections are not
supported – must use FCR.
M-EOS v9.9.5 or later
McDATA ED-5000 32-port FC director Not Supported
Multi
MultiMulti
Multi-
--
-Protocol Router
Protocol Router Protocol Router
Protocol Router I
II
Interop
nteropnterop
nteroperability
erabilityerability
erability
Brocade 7420 Not supported
Brocade 7500 and FR4-18i blade V6.2.2 and higher
4 6
McDATA SANRouters 1620 and 2640 Not Supported
NOS
NOS NOS
NOS (VDX Platform)
(VDX Platform) (VDX Platform)
(VDX Platform) I
II
Interop
nteropnterop
nteroperability
erabilityerability
erability
Brocade VDX6710, VDX6720, VDX6730 NOS v2.1.1 or later
7
Table Notes:
1
When routing to an M-EOS edge fabric using frame redirection, the M-EOS fabric must have a FOS-based product in
order to configure the frame redirection zone information in the edge fabric.
2
When directly attached to a Host or Target that is part of an encryption flow.
3
These platforms may not be directly attached to hosts or targets for encryption flows.
4
McDATA 1620 and 2640 SANRouters should not be used with FOS-based routing (FCR) for connections to the same
edge fabric.
5
FA4-18 is not supported in a DCX/DCX-4S that is running FOS v7.0 or later
6
If operating with FOS v6.2.2e
FOS v6.2.2eFOS v6.2.2e
FOS v6.2.2e
or earlier
or earlieror earlier
or earlier, Adaptive Networking QoS must be disabled when connecting to 16G FC
platform. Otherwise, ISL will segment.
7
Connectivity to FC SAN is established via VDX6730 connected to FCR running FOS v7.0.1 or later. FCR platforms
supported include 5100, VA-40FC, 5300, 7800, DCX, DCX-4S, DCX 8510-8, DCX 8510-4, 6510. For higher FCR
backbone scalability (refer to separate “Brocade SAN Scalability Guidelines” documentation for details), please use
5300, DCX, DCX-4S, DCX 8510-8, DCX 8510-4.
Zoning Compatibility
Zoning Compatibility Zoning Compatibility
Zoning Compatibility Note
NoteNote
Note:
Users are recommended to upgrade to the following versions of firmware when interoperating with a switch
running FOS v7.0 or later in the same layer 2 fabric to overcome some of the zoning operations restrictions
that otherwise exist:
Main code level
Main code levelMain code level
Main code level
Patch code levels with full zoning
Patch code levels with full zoning Patch code levels with full zoning
Patch code levels with full zoning
compatibility
compatibilitycompatibility
compatibility
FOS v6.2 FOS v6.2.2d or later
FOS v6.3 FOS v6.3.2a or later
FOS v6.4 FOS v6.4.1 or later