Release Notes

Fabric OS v7.0.2 Release Notes v1.0 Page 22 of 99
Typical
Typical Typical
Typical Power Supply Requirements
Power Supply RequirementsPower Supply Requirements
Power Supply Requirements
Guidelines
GuidelinesGuidelines
Guidelines
for Blades
for Blades for Blades
for Blades i
ii
in DCX 8510
n DCX 8510n DCX 8510
n DCX 8510-
--
-8
88
8
(For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications
(For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications
(For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications
in the 8510
in the 8510in the 8510
in the 8510-
--
-8 Backbone Hardware Reference Ma
8 Backbone Hardware Reference Ma8 Backbone Hardware Reference Ma
8 Backbone Hardware Reference Manual)
nual)nual)
nual)
Configured
ConfiguredConfigured
Configured
Number of Ports
Number of PortsNumber of Ports
Number of Ports
Blades
BladesBlades
Blades
Type of Blade
Type of BladeType of Blade
Type of Blade
DCX 8510
DCX 8510DCX 8510
DCX 8510-
--
-8
8 8
8
@110 VAC
@110 VAC @110 VAC
@110 VAC
(Redundant
(Redundant (Redundant
(Redundant
configurations)
configurations)configurations)
configurations)
DCX 8510
DCX 8510DCX 8510
DCX 8510-
--
-8
8 8
8
@200
@200@200
@200-
--
-240 VAC
240 VAC240 VAC
240 VAC
(Redundant
(Redundant (Redundant
(Redundant
configurations)
configurations)configurations)
configurations)
Comments
CommentsComments
Comments
336 8Gb ports +
QSFP ICLs
FC8-48E
(Maximum of
seven FC8-48E
blades, with one
empty port blade
slot)
Port Blade
4 Power Supplies
2 Power
Supplies
200-240VAC: 1+1
Power Supplies
110VAC: 2+2
1
Power Supplies
Max 7 FC8-48E port
blades
384 16Gb ports +
QSFP ICLs
FC16-32, FC16-48
Port Blade
Not Supported
4 Power
Supplies
200-240VAC:
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
384 8Gb ports +
QSFP ICLs
FC8-32E, FC8-48E Port Blade Not Supported 4 Power
Supplies
200-240VAC:
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
Any combination
of 8Gb or 16Gb
ports and
intelligent blades
with QSFP ICLs
FC16-32, FC16-48,
FC8-64, FC8-32E,
FC8-48E, FS8-18,
FX8-24
Intelligent
Blade
/Combination
Not Supported
4 Power
Supplies
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
when any special
purpose blade are
installed
Table
Table Table
Table 4
44
4
Power Supply Requirements for
Power Supply Requirements forPower Supply Requirements for
Power Supply Requirements for
DCX
DCXDCX
DCX
8510
85108510
8510-
--
-8
88
8
Notes:
1. When 2+2 power supply combination is used, the users are advised to configure the Fabric Watch setting for
switch marginal state to be two power supplies. Users can use the CLI switchstatuspolicyset to configure this
value if the current value is set to zero. In FOS v7.0.x, the default setting for the marginal state due to missing
power supplies is incorrectly set to zero (Defect 000349586), which will prevent Fabric Watch from generating
notifications when the switch enters the marginal state due to missing power supplies