Defect ID:
DEFECT000390650
Technical Severity:
Critical
Summary:
Device does not register FC4 type and path unable to failover
Symptom:
Device is not failing over to its alternate port if that alternate port happens to be on the upper part of
the FC8-64 port blade such as port indexes 868 to 884
Workaround:
Use port indexes 239-254
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Fabric Services
Reported In Release:
FOS6.4.2
Service Request ID:
712525
Defect ID:
DEFECT000391046
Technical Severity:
Medium
Summary:
portledtest, portloopbacktest etc diag command are updated.
Symptom:
Failure is observed when running 'portledtest -npass 10', 'portloopbacktest -lb_mode 1' test
Risk of Fix:
Low
Feature:
FOS Software
Probability:
High
Function:
Diagnostics
Reported In Release:
FOS7.0.1
Service Request ID:
712391
Defect ID:
DEFECT000391190
Technical Severity:
Medium
Summary:
snmpd failed to restart
Symptom:
SNMP no longer functioning on switch. SNMP crashed and generated a core file twice then failed to
restart.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
SNMP
Reported In Release:
FOS7.0.0
Service Request ID:
714615
Defect ID:
DEFECT000391201
Technical Severity:
Medium
Summary:
New threshold options available for bottleneck
Symptom:
User can now set alerts for congestion or latency in addition to set for both.
Risk of Fix:
Low
Feature:
Man Pages
Probability:
Low
Function:
Edit/Correct
Reported In Release:
FOS7.0.1
Defect ID:
DEFECT000391658
Technical Severity:
Medium
Summary:
Multivolume tape jobs failing over 7500/FR4-18i emulation
Symptom:
Customer gets failures on multivolume tape drive jobs over 7500/Fr4-18i jobs
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
FCIP
Reported In Release:
FOS6.4.2
Service Request ID:
701075
Defect ID:
DEFECT000392322
Technical Severity:
Medium
Summary:
Emulation should free the previously aborted exchange if the Host re-uses the oxid within R_A_TOV
of the BA_ACC.
Symptom:
FCIP Emulation not releasing aborted exchanges, potentially causing generated SCSI Busy status
sequences if the exchange is reused within 22 seconds.
Worka
round:
Disable emulation
Risk of Fix:
Low
Feature:
FCIP
Probability:
Medium
Function:
Emulation
Reported In Release:
FOS7.0.1