Release Notes

Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0 Page 47 of 99
Defect ID:
DEFECT000397135
Technical Severity:
Medium
Summary:
change Port Fencing raslog severity
Symptom:
Change Port Fencing raslog message FW- 1202 FW-1501 from Warning to Error. No functional
impact.
Risk of Fix:
Low
Feature:
Infrastructure
Probability:
Low
Function:
Other
Reported In Release:
FOS6.4.3
Defect ID:
DEFECT000397275
Technical Severity:
Medium
Summary:
Performing switchdisable,configdefault, portcfgpersistenetenable, portcfgdefault, then
portcfgpersistent enable can cause some ports to stay in "FC Disabled" state.
Symptom:
After a system config default, followed by a series of portcfg default and portcfgpersistentenable's a
few ports will still show disabled.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Medium
Function:
ASIC Driver
Reported In Release:
FOS6.4.0
Service Request ID:
724141
Defect ID:
DEFECT000397353
Technical Severity:
Medium
Summary:
When issuing the statsclear command it will return an error saying slot0 is non-existent in v7.0.1a
Symptom:
> statsclear
Invalid slot number 0 detected in chassis system.
Please use --slot option or setslot command to provide a valid slot.
Workaround:
Use slotstatsclear command
Risk of Fix:
Low
Feature:
FOS Software
Probability:
High
Function:
Fabric Services
Reported In Release:
FOS7.0.1
Service Request ID:
724465
Defect ID:
DEFECT000397402
Technical Severity:
Medium
Summary:
Soft parity errors causing disruption on BES/FS8-18
Symptom:
If a parity error occurs in the encryption path, frames may be transmitted to the destination carrying
an incorrect payload and without being marked with an error. If a parity error occurs in the decryption
path, the frame data might not be decrypted successfully.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Fabric Services
Reported In Release:
FOS6.4.2
Service Request ID:
722589
Defect ID:
DEFECT000398718
Technical Severity:
High
Summary:
VEX port on FR4-18i requires Integrated Routing license on FOS v7.0.1 and FOS v7.0.1a; previous
releases did not require license.
Symptom:
Customer can no longer import device and run traffic without Integrated Routing license on FR4-18i
Vex port.
Risk of Fix:
Low
Feature:
Legacy FCR - 7500/FR4-18i
Probability:
High
Function:
Other
Reported In Release:
FOS7.0.1