Deployment Guide

Fabric OS Command Reference 241
53-1003131-01
diagEnablePost
2
diagEnablePost
Enables the power-on self-test (POST).
SYNOPSIS diagenablepost
DESCRIPTION Use this command to enable POST. A reboot is not required for this command to take effect. POST
includes two phases: POST Phase I mainly tests hardware and POST Phase II tests system functionality.
Use the diagPost command to display the current POST status, and use diagDisablePost to disable
POST.
NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS None
EXAMPLES To enable POST:
switch:admin> diagenablepost
Config update Succeeded
Diagnostic POST is now enabled.
SEE ALSO diagDisablePost, diagPost