Deployment Guide

Fabric OS Command Reference 795
53-1003131-01
portCfgShow
2
EXAMPLES To display the port configuration settings for a single port on a Brocade DCX 8510-8:
switch:admin> portcfgshow 10/38
Area Number: 222
Octet Speed Combo: 1(16G|8G|4G|2G)
Speed Level: AUTO(HW)
AL_PA Offset 13: OFF
Trunk Port ON
Long Distance LS
VC Link Init OFF
Desired Distance 10 Km
Reserved Buffers 86
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
Locked E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
LOS TOV enable OFF
NPIV capability ON
NPIV FLOGI Logout ON
QOS E_Port AE
Port Auto Disable: ON LOSG OLS NOS LIP
Rate Limit OFF
EX Port OFF
Mirror Port OFF
SIM Port ON
Credit Recovery ON
F_Port Buffers OFF
E_Port Credits OFF
Fault Delay: 0(R_A_TOV)
NPIV PP Limit: 126
CSCTL mode: OFF
D-Port mode: ON
D-Port over DWDM: ON
Compression: OFF
Encryption: OFF
FEC: ON
To display the port configuration settings on a Brocade 5100 for a range of ports specified by their index
numbers:
switch:admin> portcfgshow -i 3-5
Speed 8G 8G 8G
Fill Word(On Active) 0 0 0
Fill Word(Current) 0 0 0
AL_PA Offset 13 .. .. ..
Trunk Port ON ON ON
Long Distance .. .. ..
VC Link Init .. .. ..
Locked L_Port .. .. ..
Locked G_Port .. .. ..
Disabled E_Port .. .. ..
Locked E_Port .. .. ..
ISL R_RDY Mode .. .. ..
RSCN Suppressed .. .. ..
Persistent Disable .. .. ..
LOS TOV enable ON .. ..
NPIV capability ON ON ON