Release Notes

Fabric OS v7.3.0a Release Notes v2.0 Page 48 of 55
/root/.java/deployment/deployment.properties
2. Launch the java control panel using below command and click on Ok button
<Network Advisor Home>\jre\bin\jcontrol
Please refer to Brocade Network Advisor release notes for more details.
In addition, users must check the “Enable Java content in the browser” box under the Security tab of
Java Control Console to allow launching WebTools from BNA server clients.
Zoning
There are limitations to zoning operations that can be performed from a FOS v6.x switch that is in the
same fabric as a FOS v7.0 or later switch if the FOS v6.x switch is not running the recommended
firmware version. Please see Fabric OS Interoperability section for details.
Miscellaneous
Users must also keep the RADIUS accounting port (Authentication Port+1) open in the firewall
to ensure proper working of the RADIUS authentication.
Using a Windows anonymous FTP server for supportsave collection:
When using anonymous ftp, to avoid long delays or failure of simultaneous supportsave
collections when AP blades are present in a director chassis, the number of unlimited
anonymous users for a Windows FTP server should be configured as follows:
Number of anonymous FTP connections = (Number of director chassis) + (Number of
installed Application Blades x 3)
RASlog message AN-1010 may be seen occasionally indicating “Severe latency bottleneck
detected”. Even though it is a “Warning” message, it is likely to be a false alarm and can be
ignored.
POST diagnostics for the Brocade 5100 have been modified beginning with FOS v6.3.1b and
v6.4.0 to eliminate an “INIT NOT DONE” error at the end of an ASIC diagnostic port loopback
test. This modification addresses BL-1020 Initialization errors encountered during the POST
portloopbacktest. (Defect 263200)
It is important to note that the outputs of slotshow p and chassisShow commands also
display the maximum allowed power consumption per slot. These are absolute maximum
values and should not be confused with the real-time power consumption on 16G blades. The
chassisshow command has a “Power Usage (Watts):” field that shows the actual power
consumed in real-time on 16G blades.
Class 3 frames that have been trapped to CPU will be discarded in the following scenarios on
DCX/DCX-4S/DCX 8510 during the following conditions:
HA failover on DCX/DCX-4S/DCX 8510 platforms while running FOS v7.0 or later firmware
Firmware upgrade from v7.0 to a later release on Brocade 300, 5100, VA-40FC, 5300,
6510
Firmware upgrade from v7.0.1 to a later release on Brocade 6505
Firmware upgrade from v7.1.0 to a later release on Brocade 6520
The QSFP information in the sfpshow output will indicate the ID field as all zeros. This is as
designed.