Release Notes

Fabric OS v7.3.0c Release Notes v1.0 Page 51 of 52
Workaround:
Disabling all problem ports with unstable light or fixing the speed of the port may help to limit the
CPU load.
Defect ID:
DEFECT000528728
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.0.0
Technology Area:
Logging
Symptom:
Raslog messages C3-1006 followed by a C3-1010 message may be seen on a switch with no further
operational impact.
Condition:
Single bit correctable parity errors may cause these raslog events on 16G blades. These error are self-
corrected and should not be reported. .
Workaround:
Please contact Brocade support for further evaluation if necessary.
Defect ID:
DEFECT000529602
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Distance
Reported In Release:
FOS7.3.0
Technology Area:
FCIP
Symptom:
Problem can occur if the TCP connections between the switches are bouncing during the tunnel
creation or establishment processing.
Condition:
During a time window, after a tunnel had informed its user of a connection request from the remote
peer, the tunnel went down. The user then accepted the connection and was returned an error
condition from the tunnel. The user did not properly check for an error return, and therefore did not
close the connection out properly