Developers Guide

Fabric OS Message Reference 179
53-1003140-01
BL-1007
5
BL-1007
Message blade #<blade number>: blade state is inconsistent with EM. bl_cflags 0x<blade
control flags>, slot_on <slot_on flag>, slot_off <slot_off flag>, faulty <faulty
flag>, status <blade status>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a failover occurred while a blade was initializing on the previously active control processor
(CP).
Recommended
Action
No action is required. The blade is reinitialized. Because reinitializing a blade is a disruptive operation
and can stop I/O traffic, you may need to stop and restart the traffic during this process.
BL-1008
Message Slot <slot number> control-plane failure. Expected value: 0x<value 1>, Actual:
0x<value 2>.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the blade has experienced a hardware failure or was removed without following the
recommended removal procedure.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
If the message persists, replace the blade.
BL-1009
Message Blade in slot <slot number> timed out initializing the chips.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the blade has failed to initialize the application-specific integrated circuit (ASIC) chips.