Developers Guide

230 Fabric OS Message Reference
53-1003140-01
CDR-1007
5
CDR-1007
Message S<slot number>,C<chip index>: Internal link errors have been reported, no hardware
faults identified, continuing to monitor for errors: flt1:0x<fault1_cnt>,
flt2:0x<fault2_cnt> thresh1:0x<threshold_used>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that some errors were found in hardware that may or may not impact the data traffic.
Recommended
Action
No action is required.
CDR-1008
Message S<slot number>,C<chip index>: HW ASIC Chip warning Level 1 type = 0x<chip error
type>.
Message Type LOG
Severity WARNING
Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may or may
not degrade the data traffic.
Recommended
Action
Restart the system at the next maintenance window.
CDR-1009
Message S<slot number>,C<chip index>: HW ASIC Chip warning Level 2 type = 0x<chip error
type>.
Message Type LOG
Severity WARNING
Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may or may
not degrade the data traffic.
Recommended
Action
Restart the system at the next maintenance window.