Developers Guide

794 Fabric OS Message Reference
53-1003140-01
SEC-1186
5
SEC-1186
Message <Security server (RADIUS/LDAP/TACACS+)> <action> Configuration.
Message Type LOG
Severity INFO
Probable Cause Indicates the RADIUS, LDAP, or TACACS+ configuration was enabled or disabled as the primary
authentication, authorization, and accounting (AAA) mechanism.
Recommended
Action
No action is required.
SEC-1187
Message Security violation: Unauthorized switch <switch WWN> tries to join fabric.
Message Type LOG
Severity INFO
Probable Cause Indicates a Switch Connection Control (SCC) security violation was reported. The specified unauthorized
switch attempts to join the fabric.
Recommended
Action
Check the SCC policy to verify the switches allowed in the fabric. If the switch should be allowed in the
fabric but it is not included in the SCC policy, add the switch to the policy. If the switch is not allowed
access to the fabric, this is a valid violation message and an unauthorized entity is trying to access your
fabric. Take appropriate action, as defined by your enterprise security policy.
SEC-1188
Message Security violation: Unauthorized device <device node name> tries to FLOGI to
index/area <port number> of switch <switch WWN>.
Message Type LOG
Severity INFO
Probable Cause Indicates a Device Connection Control (DCC) security violation was reported. The specified device
attempted to log in using fabric login (FLOGI) to an unauthorized port. The DCC policy correlates specific
devices to specific port locations. If the device changes the connected port, the device will not be allowed
to log in.
Recommended
Action
Check the DCC policy and verify the specified device is allowed in the fabric and is included in the DCC
policy. If the specified device is not included in the policy, add it to the policy. If the host is not allowed
access to the fabric, this is a valid violation message and an unauthorized entity is trying to access your
fabric. Take appropriate action, as defined by your enterprise security policy.