Messages Reference Guide

278 Fabric OS Message Reference
53-1002749-01
EM-1001
5
EM Messages
EM-1001
Message <FRU ID> is overheating: Shutting down.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the specified field-replaceable unit (FRU) is shutting down due to overheating. This event
is typically due to a faulty fan and can also be caused by the switch environment.
Recommended
Action
Verify that the location temperature is within the operational range of the switch. Refer to the Hardware
Reference Manual for the environmental temperature range of your switch.
Execute the fanShow command to verify that all fans are running at normal speeds. If any fans are
missing or not performing at high enough speed, they should be replaced.
EM-1002
Message System fan(s) status <fan FRU>.
Message Type LOG | FFDC
Severity INFO
Probable Cause Indicates that a non-bladed system has overheated and may shutdown. All fan speeds are dumped to
the console.
Recommended
Action
Verify that the location temperature is within the operational range of the switch. Refer to the Hardware
Reference Manual for the environmental temperature range of your switch.
Execute the fanShow command to verify that all fans are running at normal speeds. If any fans are
missing or are not performing at a high enough speed, they should be replaced.
EM-1003
Message <FRU ID> has unknown hardware identifier: FRU faulted.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that a field-replaceable unit (FRU) header could not be read or is not valid. The FRU is faulted.
Recommended
Action
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade by using the slotPowerOff and slotPowerOn commands or have the blade's ejector
switch cycled to run POST and verify that the blade does not have any hardware problems.
For the Brocade 300 and 6510, replace the switch.