EM-1014
5
EM-1014
Message Unable to read sensor on <FRU Id> (<Return code>).
Message Type LOG
Severity ERROR
Probable Cause Indicates that the environmental monitor (EM) was unable to access the sensors on the specified
field-replaceable unit (FRU).
Recommended
Action
Reseat the FRU. If the problem persists, replace the FRU.
EM-1015
Message Warm recovery failed (<Return code>).
Message Type LOG
Severity WARNING
Probable Cause Indicates that a problem was discovered when performing consistency checks during a warm boot.
Recommended
Action
Monitor the switch. If the problem persists, restart or power cycle the switch.
EM-1016
Message Cold recovery failed (<Return code>).
Message Type LOG
Severity WARNING
Probable Cause Indicates that a problem was discovered when performing consistency checks during a cold boot.
Recommended
Action
Monitor the switch.
If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP