Messages Reference Guide

366 Fabric OS Message Reference
53-1002749-01
FCR-1075
5
FCR-1075
Message Zone Name configuration is larger than <Zone Name Limit> characters in the edge
fabric connected to port <port number>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the zone name configuration size created in the connected fabric exceeds the maximum
supported by the FC Router. This size is equal to the total number of characters used by all the zone
names in the edge fabric zoning database.
The limit includes both LSAN and non-LSAN zone names defined in the zoning name database of the
edge fabric.
Recommended
Action
Limit the zone configuration size in the edge fabric connected to this port by either reducing the number
of zones or changing the zone names to smaller names.
FCR-1076
Message Port <port number> disabled, system only supports <maximum fds> front domains.
Message Type LOG
Severity INFO
Probable Cause Indicates that the maximum number of supported front domains was exceeded. To enable the specified
port, disable any other operational front domain and then re-enable the port.
Recommended
Action
Make sure to remain within the maximum number of supported front domains.
FCR-1077
Message Port <port number> rejected fabric binding request/check from the M-Model switch;
<Fabric ID>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that an M-Model edge switch attempted to either activate or check the fabric binding. This port
will be disabled if this event occurred during a check of fabric binding and not during failure to activate
fabric binding. The error is caused when the binding list details configured on the M-Model switch do not
match with the currently configured front port domain ID and WWN of the EX_Port on which this
operation was attempted.
Recommended
Action
Ensure that the M-Model switch has the same currently configured details such as the front port domain
ID and WWN of the EX_Port on which this operation was attempted.