Messages Reference Guide

652 Fabric OS Message Reference
53-1002749-01
PLAT-1003
5
PLAT-1003
Message <Info message> Slot <Blade Slot number> C/BE: 0x<Captured Command/Byte-Enables
data> ADBUS: 0x<Captured AD bus data> misc_intr 0x<Bridge reset interrupts>.
Message Type LOG | FFDC
Severity CRITICAL
Probable Cause Indicates that peripheral component interconnect (PCI) bus hang was detected.
Recommended
Action
Replace the field-replaceable unit (FRU).
PLAT-1004
Message Switch has older FPGA rev 0x<FPGA version already installed in HW>. Upgrade to
newer rev 0x<FPGA version which Fabric OS carries> using the fpga_update command.
Message Type LOG | FFDC
Severity CRITICAL
Probable Cause Indicates that Fabric OS has older field-programmable gate array (FPGA) version. This message is
applicable only to Brocade 5470.
Recommended
Action
Upgrade FPGA to new version.
PLAT-1072
Message The chassis is disabled because no Core Blades are available. Insert/replace one
or both Core Blades and run chassisenable.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the chassis has been disabled because of the unavailability of the core blades. There must
be at least one core blade in enabled state for the chassis to be considered ready. All core blades are
either missing, faulted, or powered off. This results in all logical switches (and ports) being disabled.
Recommended
Action
Make sure that all core blade slots have core blades inserted and their ejector switches are closed.
Power on core blades that are powered off, and power cycle or replace the core blades that are faulted.
Run the chassisenable command to re-enable the ports.
Running the fastboot or reboot command will also result in enabling the logical switches and ports.