SEC-1099
5
SEC-1099
Message Please enable your switch before running secModeEnable.
Message Type LOG
Severity ERROR
Probable Cause Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Action
Run the fabricShow command to verify that the fabric is still consistent. All the switches should be in the
ready state. If a switch is in the error state, the database may not be correctly updated for that specific
switch.
SEC-1100
Message FCS switch present. Command terminated.
Message Type LOG
Severity ERROR
Probable Cause Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Action
Run the fabricShow command to verify that the fabric is still consistent. All the switches should be in the
ready state. If a switch is in the error state, the database may not be correctly updated for that specific
switch.
SEC-1101
Message Failed to enable security on all switches. Please retry later.
Message Type LOG
Severity ERROR
Probable Cause Indicates the security enable failed on the fabric because one or more switches in the fabric are busy.
Recommended
Action
Verify that the security event was planned. If the security event was planned, run the secFabricShow
command to verify that all switches in the fabric are in the ready state. When all switches are in the ready
state, retry the operation.