MIB Reference Guide

82 Fabric OS MIB Reference
53-1002750-01
fcFeStatus group
4
fcFxPortPhysLastChange
1.3.6.1.2.1.75.1.2.2.1.3
Read only The value of sysUpTime at the time the Fx_Port entered its current
operational status. A value of 0 indicates that the Fx_Port
operational status has not changed since the agent last restarted.
fcFxPortPhysRttov
1.3.6.1.2.1.75.1.2.2.1.4
Read only The Receiver_Transmitter_Timeout value of the Fx_Port. This is used
by the receiver logic to detect loss of synchronization. This value is
displayed in milliseconds.
fcFxLoginTable
1.3.6.1.2.1.75.1.2.3
Not accessible This table contains one entry for each Fx_Port in the fabric element
and the service parameters that have been established from the
most recent fabric login, whether implicit or explicit.
fcFxloginEntry
1.3.6.1.2.1.75.1.2.3.1
Not accessible An entry containing service parameters established from a
successful fabric login.
fcFxPortNxLoginIndex
1.3.6.1.2.1.75.1.2.3.1.1
Not accessible The associated Nx_Port in the attachment for which the entry
contains information.
fcFxPortFcphVersionAgre
ed
1.3.6.1.2.1.75.1.2.3.1.2
Read only The version of FC-PH that the Fx_Port has agreed to support from
the fabric login.
fcFxPortNxPortBbCredit
1.3.6.1.2.1.75.1.2.3.1.3
Read only The total number of buffers available for holding Class 1
connect-request, and Class 2 or Class 3 frames to be transmitted to
the attached Nx_Port. It is for buffer-to-buffer flow control in the
direction from Fx_Port to Nx_Port. The buffer-to-buffer flow control
mechanism is indicated in the respective fcFxPortBbCreditModel.
fcFxPortNxPortRxDataFiel
dSize
1.3.6.1.2.1.75.1.2.3.1.4
Read only The Receive Data Field Size of the attached Nx_Port. This is a binary
value that specifies the largest Data Field Size for an FT_1 frame
that can be received by the Nx_Port. The value is a number of bytes
in the range 128 to 2112, inclusive.
fcFxPortCosSuppAgreed
1.3.6.1.2.1.75.1.2.3.1.5
Read only Indicates that the attached Nx_Port has requested the Fx_Port for
the support of classes of services and the Fx_Port has granted the
request.
fcFxPortIntermixSuppAgr
eed
1.3.6.1.2.1.75.1.2.3.1.6
Read only A variable indicating that the attached Nx_Port has requested the
Fx_Port for Intermix support, and the Fx_Port has granted the
request. This flag is only valid if Class 1 service is supported.
fcFxPortStackedConnMo
deAgreed
1.3.6.1.2.1.75.1.2.3.1.7
Read only Indicates whether the Fx_Port has agreed to support stacked
connect from the fabric login. This is only meaningful if Class 1
service has been agreed to.
fcFxPortClass2SeqDelivA
greed
1.3.6.1.2.1.75.1.2.3.1.8
Read only Indicates whether the Fx_Port has agreed to support Class 2
sequential delivery from the fabric login. This is only meaningful if
Class 2 service has been agreed to.
Valid values:
yes (1) - The Fx_Port has agreed to support Class 2 sequential
delivery from the fabric login.
no (2) - The Fx_Port has not agreed to support Class 2
sequential delivery from the fabric login.
TABLE 28
Object and OID Access Description