MIB Reference Guide

146 Fabric OS MIB Reference
53-1002750-01
Switch system group
6
swSensorValue
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.4
Read only The current value (reading) of the sensor.
The value -2147483648 represents the maximum value of integer
value; it also means that the sensor does not have the capability to
measure the actual value. In v2.0, the temperature sensor value is
in Celsius, the fan value is in RPM (revolutions per minute), and the
power supply sensor reading is unknown.
The unknown value -2147483648 indicates the maximum value of
integer value.
swSensorInfo
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.5
Read only Additional information on the sensor. It contains the sensor type
and number, in textual format; for example:
SLOT #0: TEMP #3
FAN #1
Power Supply #1
Return values for the Brocade 12000, 24000, and 48000 directors
depend upon the configuration of your system.
swTrackChangesInfo
1.3.6.1.4.1.1588.2.1.1.1.1.23
Read only Track changes string; for trap only.
If there are no events to track, the default return value is “No event
so far.”
If there are events to track, the following are valid return values:
Successful log in
Unsuccessful log in
Logout
Configuration file change from task [name of task]
Track-changes on
Track-changes off
swID
1.3.6.1.4.1.1588.2.1.1.1.1.24
Read only With VF-enabled fabric, the number of switches will be 0 to 128.
swEtherIPAddress
1.3.6.1.4.1.1588.2.1.1.1.1.25
Read only Supported in Fabric OS v6.2.0 and later releases.
The IP address of the Ethernet interface of this switch.
swEtherIPMask
1.3.6.1.4.1.1588.2.1.1.1.1.26
Read only The IP mask of the Ethernet interface of this switch.
swFCIPAddress
1.3.6.1.4.1.1588.2.1.1.1.1.27
Read only The IP address of the FC interface of this switch.
swFCIPMask
1.3.6.1.4.1.1588.2.1.1.1.1.28
Read only The IP mask of the FC interface of this switch.
swIPv6Address
1.3.6.1.4.1.1588.2.1.1.1.1.29
Not
accessible
The IPv6 address. This object is not accessible.
swIPv6Status
1.3.6.1.4.1.1588.2.1.1.1.1.30
Not
accessible
The current status of the IPv6 address. This object is not
accessible.
swModel
1.3.6.1.4.1.1588.2.1.1.1.1.31
Read only Indicates whether the switch is 7500 or 7500E.
swTestString
1.3.6.1.4.1.1588.2.1.1.1.1.32
Not
accessible
Presence of this string represents test trap.
swPortList
1.3.6.1.4.1.1588.2.1.1.1.1.33
Not
accessible
This string represents the list of ports and its WWN when the ports
are moved from one switch to another.
TABLE 45