MIB Reference Guide

Fabric OS MIB Reference 171
53-1002750-01
Bloom performance monitor group
6
swBlmPerfEERefKey
1.3.6.1.4.1.1588.2.1.1.1.23.2.
1.2
Read only This object identifies the reference number of the counter. This
reference is a number assigned when a filter is created. In the SNMP
Index, start with one instead of 0, add one to the actual reference
key.
swBlmPerfEECRC
1.3.6.1.4.1.1588.2.1.1.1.23.2.
1.3
Read only End-to-end CRC error for the frames that matched the SID-DID pair.
swBlmPerfEEFCWRx
1.3.6.1.4.1.1588.2.1.1.1.23.2.
1.4
Read only Get end-to-end count of Fibre Channel words (FCW) received by the
port that matched the SID-DID pair.
swBlmPerfEEFCWTx
1.3.6.1.4.1.1588.2.1.1.1.23.2.
1.5
Read only Get end-to-end count of Fibre Channel words (FCW) transmitted by
the port that matched the SID-DID pair.
swBlmPerfEESid
1.3.6.1.4.1.1588.2.1.1.1.23.2.
1.6
Read only Gets DID information by reference number.
swBlmPerfEEDid
1.3.6.1.4.1.1588.2.1.1.1.23.2.
1.7
Read only Gets SID information by reference number. SID (Source Identifier) is
a 3-byte field in the frame header used to indicate the address
identifier of the N_Port from which the frame was sent.
swBlmPerfFltMntTable
1.3.6.1.4.1.1588.2.1.1.1.23.3
Not
accessible
Filter-based monitoring counter.
To configure the predefined monitors on port, use the fmmonitor
--addmonitor <frame_type> -port <slot/port_list> command.
To configure the user-defined monitors on port, use one of the
following commands:
fmmonitor --create <frame_type> -pat <bitpattern> [-port
<slot/port_list>]
fmmonitor --addmonitor <frame_type> -port <slot/port_list>
swBlmPerfFltMntEntry
1.3.6.1.4.1.1588.2.1.1.1.23.3.
1
Not
accessible
Filter-based monitoring counter for given port.
swBlmPerfFltPort
1.3.6.1.4.1.1588.2.1.1.1.23.3.
1.1
Read only This object identifies the port number of the switch.
swBlmPerfFltRefkey
1.3.6.1.4.1.1588.2.1.1.1.23.3.
1.2
Read only This object identifies the reference number of the filter. This
reference number is assigned when a filter is created. In the SNMP
Index, start with one instead of 0, add one to actual reference key.
swBlmPerfFltCnt
1.3.6.1.4.1.1588.2.1.1.1.23.3.
1.3
Read only Get statistics of filter-based monitor. Filter-based monitoring
provides information about a filter hit count, such as:
Read command
SCSI or IP traffic
SCSI Read/Write
swBlmPerfFltAlias
1.3.6.1.4.1.1588.2.1.1.1.23.3.
1.4
Read only Alias name for the filter.
TABLE 57
Object and OID Access Description