Release Notes

Fabric OS v7.0.1 Release Notes v1.0 Page 31 of 67
Defects
Open Defects in Fabric OS v7.0.1
This section lists defects with High or Medium Technical Severity open in Fabric OS v7.0.1 as of December
15, 2011. While these defects are still formally ―open,‖ they are unlikely to impede Brocade customers in
their deployment of Fabric OS v7.0.1 and have been deferred to a later release.
None of these defects have the requisite combination of probability and severity to cause significant
concern to Brocade customers.
Note that when a workaround to an issue is available, it is provided; otherwise, no recommended
workaround is available at this time.
Defect ID: DEFECT000329211
Technical Severity: High
Summary: Encountered a DataPath panic on the Brocade 7800 when portcfgdefault was executed on
VE port (with a circuit in test mode)
Symptom: User experiences temporary FCIP traffic disruption after executing portcfgdeault on a VE
port that has TPERF running.
Workaround: Avoid executing "portcfgdefault" on a VE port that has TPerf running.
Feature: FCIP
Function: FCIP Port
Probability: Low
Found in Release: FOS7.0.0
Defect ID: DEFECT000355346
Technical Severity: High
Summary: Replacing a failed FX8-24 blade may result in one circuit on a crossport configured tunnel
getting stuck "In Progress..."
Symptom: A crossport circuit fails to complete initialization and the user doesn't have the full
bandwidth of the tunnel.
Feature: FCIP
Function: FCP TCP/IP Stack
Probability: Low
Found in Release: FOS7.0.0
Defect ID: DEFECT000369926
Technical Severity: High
Summary: Emulated I/O that traverses multiple hops in a VF base fabric and one of those links is a VE
tunnel with FastWrite enabled.
Symptom: FastWrite fails in a multihop VE-XISL configuration.
Feature: Striker/Spike Platform
Services
Function: VF
Probability: High
Found in Release: FOS7.0.1
Defect ID: DEFECT000381543
Technical Severity: High
Summary: Device Discovery between backbone fabric and edge fabric fails after changing FCR switch
domain ID.
Symptom: Host fails to discover target across backbone to edge routing.
Workaround: Reboot the hosts.
Feature: 8G FCR
Function: Other
Probability: Medium
Found in Release: FOS7.0.1