Defect ID: DEFECT000369286
Technical Severity: Medium
Summary: Inconsistency in handling of unsupported port speed configuration after replacing an FC16-
xx blade with an FC8-xxE blade.
Symptom: After replacing an FC16-xx blade with an FC8-xxE blade, ports previously configured to fixed
10G speed will be reset to auto speed negotiation while ports previously configured to fixed
16G will be persistently disabled.
Workaround: Manually correct the configured port speed and reenable the port.
Feature: 16G ASIC Driver
Function: General
Probability: High
Found in Release: FOS7.0.1
Defect ID: DEFECT000371302
Technical Severity: Medium
Summary: CEE/FCoE: protocol spanning tree config is not visible after spanning tree shut/no shut
Symptom: If the customer changes the path cost to custom and does a shut/no shut the configuration
will have flat set as standard but rest of the config will remain as custom.
Workaround: Reconfigure port-channel path-cost custom‖ and then configure ―port-channel path-cost
standard".
Feature: CEE-LAYER2
Function: STP
Probability: Medium
Found in Release: FOS7.0.1
Defect ID: DEFECT000373589
Technical Severity: Medium
Summary: The error message for a duplicate user assigned FAPWWN will show the slot/port as -1/-1 if
the port is in a different logical switch.
Symptom: If the user attempts to assign a WWN that has already been assigned to a port in a
different logical switch, the following message is displayed:
"Error: Virtual Port WWN is already mapped (FID <xxx>, Switch port -1/-1)."
This does not indicate the actual physical port with the duplicate WWN assignment.
Workaround: Login to the FID indicated in the error message and issue "fapwwn --show all" to identify
which port has the WWN already assigned.
Feature: Fabric Provisioning
Function: CLI
Probability: High
Found in Release: FOS7.0.1
Defect ID: DEFECT000374924
Technical Severity: Medium
Summary: Port Admin Dialog: FC8-32E and FC8-48E blades will list speed combo values which are not
supported on these platforms.
Symptom: User will see speed combo values for FC8-32E and FC8-48E blades, but these settings are
not valid for these blade types.
Feature: WebMgmt
Function: Ports Admin
Probability: High
Found in Release: FOS7.0.1