Release Notes

Closed with Code Change Defects in Fabric OS v7.0.1
Fabric OS v7.0.1 Release Notes v1.0 Page 43 of 67
Defect ID: DEFECT000317392
Technical Severity: Medium
Summary: systemverification failing on 7800.
Symptom: systemverfication test fails
Feature: Diagnostics
Function: Other
Probability: Low
Found in Release: FOS6.3.1
Where Else Fixed: FOS7.0.0 GA
Defect ID: DEFECT000319548
Technical Severity: Medium
Summary: ceeportloopbacktest and ceeportledtest does not properly process all parameters on the
Brocade 8000
Symptom: Customer cannot utilize all options of the CEE port diagnostic tests
Feature: Diagnostics
Function: Other
Probability: High
Found in Release: FOS6.4.0
Service Request ID: 451771
Where Else Fixed: FOS7.0.0 GA, FOS6.4.1 b
Defect ID: DEFECT000335811
Technical Severity: Medium
Summary: Brocade 5450 switches crashed when latest version of enclosure management SW was
used.
Symptom: Brocade 5450 platform may panic if used with newer version of MMB that uses new ISMIC
block which was previously not supported.
Workaround: Use initial qualified MMB version
Feature: Field Escalation
Function: Panic / OOM
Probability: Low
Found in Release: FOS6.2.0
Service Request ID: 530085
Where Else Fixed: FOS6.4.2 a
Defect ID: DEFECT000336933
Technical Severity: Medium
Summary: Switch sends ELP to device after the device sends FLOGI during power-up sequence
Symptom: When connected to 4G switch, during a specific storage device power-up sequence, host
cannot access target.
Feature: Field Escalation
Function: ASIC Driver
Probability: Low
Found in Release: FOS6.1.2
Service Request ID: 444823
Where Else Fixed: FOS6.4.2